OPTIONS Measuring range/output
Cabled socket Body material Operating levers Alternative output Flameproof enclosure
90°, 180°, 270° or 360° with Analogue voltage output 360° only with Digital PWM output
2m or 5m cabled socket assemblies available (rated -25 to + 90°C only) Optional anodised aluminium or corrosion resistant stainless steel housing 155 or 230mm long. See details on page 7
Synchronous Serial Interface (SSI) output can be offered to high volume OEMs Please ask our technical sales team for details on our capability
AVAI LABILI TY
All standard configurations can be supplied within ten days from the factory
O RD ERI NG CODES
SRH880/...../...../.....
Measuring range/ output 360P = 360°PWM 360A = 360° Analogue 270A = 270° Analogue 180A = 180° Analogue 090A = 90° Analogue
Body material AL = Aluminium SS = Stainless steel
Cabled socket 00 = None
02 = 2m
05 = 5m
DIMENSIONS
Notte: drawings not to scale
LEVER OPTIONS
Accessories (order separately) lever SA202195/MK1 L = 155 lever SA202195/MK2 L = 230
L
ò
>oooo 0
o
_ 7 holes
T tapped M8 through
o o
il
_
1JLÔ.
- -
20.0
u t
Pin No. Cable colour
Description
5j\Pi n 3
Cabled socket
Pin 4>
2 metre long No. X61-169-102
1 Brown
0V Supply (GND)
(fi
°\\\Pin 2
(Hirschmann No. 934 401-203 2m)
3 Hue
+ V Supply
HL
J4f(n/c)
5 metre long No. X61-169-105
4 Hack
Output
(Hirschmann No. 934 401-202 5m)
2 -
Not connected
Orientationlug
M12 connector
Output increases with CW rotation viewed on
shaft
ELECTRI CAL
CONN ECTI ONS
Straight cabled socket
E series M12 to IEC 60947-5-2, PURjacket
Conforms to VDE 0472 part 804 Cable temperature range -25 to + 90°C
When connecting the sensor, care should be taken with the correct connections. The sensor is provided with indefinite reverse polarity protection and short circuit protection between output (Pn 4 - Black) to GND (Pin 1 - Brown), but if the output (Pn 4 - Black) is connected to the supply it will result in device failure.
7