JC120
Developed for applications where ergonomics and system integrity are paramount, the JC120 is a minimum width, low profilejoystick that provides smooth, precise fingertip control in one axis with a choice of two lever lengths. The JC120 is sealed to IP66to enable it to operate in extreme environments. Standing only 54 or 64mm high, the JC120 is less susceptible to unintentional
operation. With all of the components contained within the handle, it is ideal for mounting in low profile panels and arm rests.Installation time has been reduced through the use of a standard
electronic connector, and the joystick has been designed for
maintenance-free operation throughout on operating life of greater than five million operations. An optional neoprene boot is
available for the short handle version, allowing operation in environments where aggressive materials are present, protecting
from dust and dirt ingress.Typical applications include remote control chest packs and the control of construction, agricultural or material handlingequipment. Short handleShort handle with bootLong handle 3.1*3.8*2.3* 5.1*13.2*3.4*Full deflection
50*50*35*Full deflection
±30±30±30 (or 0-60)
Self centeringSelf centeringSelf centering or end return
>5 million>1million for boot (replaceable)>5 million
454745
*At top of handle-25 to +70-40 to +85
IP66 >
PERFORMANCEMECHANICAL
Breakout forceN Operating forceN
Maximum allowable forceN
Lever operating angle°
Lever action
Expected life (operations)
Weightg >
ENVIRONMENTAL
Operating temperature°C
Storage temperature°C
Environmental protection above flange >
† IEC 60529†
Industrial seal integrity can only be achieved when using sealing gasket supplied and screws are tightened to 1Nm. Sealing gasket not required when neoprene boot is fitted to short handle version.Virtually infinite4 or 5
±28
0-100, 10-90 or 25-75 of input (±2%)
48 - 52 of applied voltage
2.5 either side of center
32
Greater than 0.1**
0.25 (no load)** The long life resistive elements require a high impedance load in the wiper circuit to minimise the current flowing through the wiper for optimum conditions5 either side of center35
10
2 (resistive)
150 Ω >
ELECTRICAL
Power dissipation @ 20°CW >
Analogue Track
ResolutionTrack resistance (±20%)k Ω Track electrical angle°
Output voltage range%
Center tap voltage (no load)%
Center tap angle°
Supply voltage - maximumVdc
Wiper circuit impedanceM >
Switch - Directional or Center Off
Switch operating angle°Supply voltage - maximumVdc
Load resistance - minimumk Ω Ω Load current - maximummA
Typical contact resistance >
10