EICT

SIGNAL CONDITIONING MODULE

The EICT signal conditioning module has been specifically designed to operate the ICTrange of contactless linear position transducers. This module, housed in a high strength IP66 enclosure, incorporates a high performance circuit that drives the transducer and provides a choice of output signals with zero and span adjustment for simple user configuration. Maximum recommended distance between transducer and EICT module is 10m.

PERFORMANCE

Supply voltage, unregulated
Vdc 10 -60 or ±(10 -30) for standard output voltage range (
† † EICT only)10
limited to 13.5 min. on certain ranges - see options table Ω - 30 or ±(10 - 30) for extended output voltage range ( VM card fitted)10 - 30 or ±(10 -30) for current output ( Frequency responseHz Line regulation Power on settlement Output adjustment rangezero adjustment gain adjustmentOperational temperature°C Storage temperature °C Temperature stabilityppm/°C EMC Immunity level (see note 2)EN61000-6-2: 10kHz to 1GHzTransducer types Mechanical housingWeight maximumg CM card fitted)10 maximum (19 with Supply currentmAOutput voltage signalVdc Output current signalmA Output ripple mVrms Output load VM card fitted, 12.6 plus output current with CM card fitted)0.5-4.5 See details on page 9 for additional output options 4-20 See details on page 9 for options <5 10k minimum (resistive to 0V line) 30 (-3dB) [equivalent to 5mS output lag] <0.001% output span/Volt Within 0.25% of final output in less than 300 milliseconds-10 to 60% of span40 to 110% of span 0 to +70 -40 to +85 200 (300 if VM card fitted) Threat 100V/m : derangement <0.05% FS (Metal housing, adjacent to transducer) Threat 10V/m : derangement <0.05% FS (Standard EICThousing, 1m cable) Will only operate Penny+Giles ICT range of transducers Corrosion resistant enclosure sealed to IP66, with detail to fit rail DIN EN50022 or EN50035 or bulkhead mount via four M5 screws.105

OUTPUTCHARACTERISTICS

EICT with VMcard fitted10 - 30Vdc supply Notes:
4.5 2.5 5 13.5-30Vdcsupplyonly OutputVoltageVdc 0.5 OutputVoltageVdc 05 010 ICT transducer stroke ICT transducer stroke EICT with CMcard fitted10 - 30Vdc or ±(10 - 30) Vdc supply EICT standard unit10 - 60Vdc supply EICT with VM card fitted10 - 30Vdc or ±(10 - 30) Vdc supply
ABNote: A and B outputsonly available with a ±(13.5 - 30) Vdc supply -2.5+2.5 -5+5 OutputVoltageVdc OutputCurrentmA -7.5+7.5 020 -10+10 ICT transducer stroke4 ICT transducer stroke0 Full details on installation and set-up are included in the manual supplied with the EICT module. 1. 2.For EMC Immunity levels above 10V/m, please contact our technical sales team to discuss your application. Special housings have been developed to provide increased immunity to EMC. The ICT transducer is supplied with a Sensor Calibration Module Card (SCMC) which is calibrated to match the transducer electrical stroke. This card must be inserted into the EICT signal conditioning unit before operation. The EICT is user configurable for input and output options.