SIGNALCONDITIONING
See page 8 for full EICT module performance and dimensions+10 to +60 nominal0.5 to 4.50 to 5, 0 to 10, ±2.5, ±5, ±7.5, ±10 (using Voltage Module VM output option card)
4 -20 (using Current Module CM output option card)The transducer is supplied with a Sensor Calibration Module Card (SCMC) which is calibratedto match the transducer electrical stroke. This card must be inserted into the EICT signal
conditioning unit before operation. Full details on installation and set-up are included in the manual supplied with the EICT
module. Input voltageVdcOutput voltagestandardVdc
options VdcOutput current - optionmA
DIMENSIONS
Note: drawings not to scale
20 20Stroke length + 7532 >
ø25.00024.967 ICT0100/IN/TM or TU internal flange threaded core- (M) metric M8x1.25
(U) unified 5/16in-24UNFICT100/IN/S internal flange sleeved core.ICT100/EM or EU/T threaded flange threaded core.ICT100/EM or EU/S threaded flange sleeved core.ICT100/RM or RU/T reverse threadedflange, threaded core.ICT100/RM or RU/S reverse threadedflange, sleeved core.
35 Electrical strokeExtensionlimit Internal stop4 >
ø10.10Body 12.50 See flange detail A >
ø14Sleeve ø18 Stroke length + 65Rear sealingIP67 10 12.70 19.30 3 core cable 19/0.125 PTFEsheathed, 90% braidedscreen, FEP outer jacket.All styles 1 or 6m long.See flange detail B 10Flange 22.22 A/FM and U Thread M20x1.5 (M)or 3/4" 16-UNF (U) 19.30 12.70 See flange detail B 10 Flange Detail A Flange Detail B 4.8 R0.5R0.5 >
ø20 ø21.00/20.90 ø25.00/24.96 45° 30° >
ø16.8016.70 4.35 3.00 >
ThreadM20x1.5or3/4"-16UNF 322013 >
ELECTRICALCONNECTIONS
Coil +veCoil -ve
ExtendRetractCore GreenYellowBlueScreenNot connected 3 core cable: FEP sheathed 1m or 6mlong with PTFE insulated 19/0.125 cores.
90% braided screen. Recommended cable minimumbend radius is 10mm.
Case 7