Steam Traps - Pennant Engineering - #9

/ 101


catalogue search
P. 01
P. 02
P. 03
P. 04
P. 05
P. 06
P. 07
P. 08
P. 09
P. 10
P. 11
P. 12
P. 13
P. 14
P. 15
P. 16
P. 17
P. 18
P. 19
P. 20
P. 21
P. 22
P. 23
P. 24
P. 25
P. 26
P. 27
P. 28
P. 29
P. 30
P. 31
P. 32
P. 33
P. 34
P. 35
P. 36
P. 37
P. 38
P. 39
P. 40
P. 41
P. 42
P. 43
P. 44
P. 45
P. 46
P. 47
P. 48
P. 49
P. 50


See other catalogues for Pennant Engineering
You may also be interested in

Drain, Control valve, Valve, Air eliminator, Condensate drain


Text version of the page
Untitled table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:7.00pt "Arial", sans-serif; } .font1 { font:8.00pt "Arial", sans-serif; } .font2 { font:9.00pt "Arial", sans-serif; } .font3 { font:10.00pt "Arial", sans-serif; } .font4 { font:12.00pt "Arial", sans-serif; } .font5 { font:12.60pt "Arial", sans-serif; } .font6 { font:21.00pt "Arial", sans-serif; } PT14 Thermodynamic Steam Traps DESCRIPTION: Thermodynamic steam trap with full stainless steel internais. Best suited for high pressure line drains with lowto medium condensate loads. SALIENT FEATURES: • Complete stainless steel internals ensure better mechanical & corrosion resistance properties. • Condensate entrybelow the disc, concentrictothe disc/seat ensures a clean & parallel lift of the disc with reference to the seat, eliminating localized wear & tear. • The disc & seat are fully hardened by a special hardening process, to withstand continuous, prolonged operation. • Perfectshutoff, nosteam loss. • Robust, maintenance free, fully guaranteed. SIZES:DN 15,20,25 CONNECTIONS : Socket weld / Butt weld Non IBR1/IBRapproved. LIMITING CONDITIONS: PMA: Max. allowable pressure 250 bar(g) TMA: Max. allowable temp.* 537°C Maximum operating back pressure atthe outlet should not exceed 50% of the inlet pressure Max. operating pressure 175 bar(g) Minimum differential pressure for satisfactory operation 5 bar Cold hydro test pressure 500 bar(g) MAINTENANCE: The disc and seat should be inspected for wear. All worn or damaged parts should be replaced with new spares. The disc seat is not replaceable. Ensure that all gaskets are replaced every time the trapisdismantled. IMPORTANT: • To prevent water logging, it is required that the line be drained using the bypass, at start-up. • The trap should be installed as close as possible to the equipment to be drained. • For new pipe lines, ensure that the lines are properlyflushed, priortofitting the trap. * Can be supplied for highertemp. on request. INSTALLATION: The trap will operate in any position but the preferred installation is in a horizontal position with the disc seat cover on top. Full port isolating valves should be installed upstream and downstream of the trap. After the first 24 hours of service the cover nuts should be checked fortightness. Indian Boiler regulations

pageCatalog pdf di En 2012-05-22-31