PRK-63
Replacement Module ForPennant Float & Thermostatic Steam Trap
DESCRIPTION:
Completely assembled module can renew the old trap easily & in a short span of time without disturbing the trap connections.
The module consists of the trap cover with complete float mechanism and air vent fitted in ready to install condition. Cover gasket & name plate are also included which may be needed at the point of installation.
INSTALLATION :
1. Check the trap nameplate to ensure that the correct replacement module is being installed.
2. Isolate the trap from both upstream & downstream pressure. Allow trap to cool.
3. Remove the cover by unscrewing the bolts from the body.
4. Remove the old gasket & ensure that gasket surface isclean.
5. Clean the body thoroughly & check for its soundness.
6. Fit the new assembled module & cover gasket on to the trap body. Ensure that the float mechanism on the cover is at the lower end & air vent assembly at the top end.
7. Tighten the cover bolts after placing the name plate. Tighten the bolts in a cross pattern to a torque of 15-19Nm.
8. Open the isolating valves gradually to put the trap back into the service.
PENNANT Model
Ordrering Code
DN20,25
PT63-15
PRK63 015 100
DN32
PT-63-15
PRK63 015 125
DN20,25
PT63-30
PRK63 030 100
DN32
PT63-30
PRK63 030 125
DN20,25
PT63-75
PRK63 075 100
DN32
PT63-75
PRK63 075 125
DN20,25
PT63-125
PRK63 125 100
DN32
PT63-125
PRK63 125 125
LIMITING CONDITIONS:
PMA: Max. allowable pressure
16bar(g)
TMA: Max. allowable temperature
220 °C
TMO: Max. operating temperature
220 °C
PMO: Max. operating pressure : PT63-15
1 bar(g)
PT63-30
2 bar(g)
PT63-75
5.25 bar(g)
PT63-125
8.75 bar(g)
REPAIR KIT CONSISTS OF
PART
DESCRIPTION
A
Cover with whole mechanism mounted
B
Gasket
C
Name plate
Local regulations may restrict the use of this product below the conditions quoted. Limiting conditions refer to standard connections only. In the interest of development and improvement of the product, we reserve the right to change the specifications without prior notice.
nCllllililT USA - 10 Parsonage Road, Suite 312, Edison, NJ, Tel.: 877-597-TRAP(8727) Fax:1-866-682-1244. ICFmmmwtFmE Email: info@pennantcorp.com Website: www.pennantcorp.com
INDIA - S.No. 116 (New), Gat No. 976 (Old), Wadki, Taluka Haveli, Pune - 412 308, INDIA.
Tel.: +91 (0) 20 2698 9709, Telefax: +91 (0) 20 2698 9470 §
Email: enq@pennantindia.com Website www.pennantindia.com |
|
|