Catalogue excerpts

Reproduction of this page is strictly prohibited. P.A.    = Open length P.C.    = Closed length Stroke = Open length - closed length B = Outside width a = Outside height x = Fold height Formula for calculating the CLOSED LENGTH AP = Opening of 1 fold = x -2 - 8 SM = Fabric thickness * SS = Stiffener thickness * SF = Flange thickness * P.A. NP = Number of folds =    ' ' + 2 AP P. C.= (SM -8 + SS) -NP + (SF -2) * See materials list on page 31. This data sheet shows only one type of Thermic-Welded Cover that we manufacture . Contact our engineering department for other types . Example: Given that:    Fold height = 15 mm Open length = 1000 mm Opening of 1 fold = 15 x 2 - 8 = 22 1000 Number of folds =    -+ 2 = 48 Closed length    = 3 x 48 + 4    = 148 Closed length = 148 mm * We hypothesize the fabric material with code "TEMAT015" (see materials list on page 31) ** We hypothesize that the stiffener is 1 mm thick *** We hypothesize that the flange is 2 mm thick (see materials list on page 31)

 Open the catalogue to page 1

Reproduction of this page is strictly prohibited. P.A.    = Open length P.C.    = Closed length Stroke = Open length - closed length Formula for calculating the CLOSED LENGTH B = Outside width a = Outside height x = Fold height AP = Opening of 1 fold = x -2 - 16 SM = Fabric thickness * SS    = Stiffener thickness * SF    = Flange thickness * PA NP = Number of folds= ap + 2 P. C. = (SM -8 + SS) -NP + (SF -2) * See materials list on page 31 This data sheet shows only one type of Thermic-Welded Cover that we manufacture Contact our engineering department for other types . Example Given that:    Fold...

 Open the catalogue to page 2

FLAT COVERS • Standard productsTHERMIC-WELDED COVER WITH FLEXIBLE LAMINATIONSVertical working position only Reproduction of this page is strictly prohibited. P.A. = Open length    B    = Outside width P.C. = Closed length    a    = Outside height Stroke = Open length - closed    length    x    = Fold height Formula for calculating the CLOSED LENGTH x(mm) Opening of 1 fold = (x- 2) - 16 SM = Fabric thickness * SS = Stiffener thickness * SF = Flange thickness * NP = Number of folds = Example Given that: Fold height = 30 mm Open length = 1000 mm * See materials list on page 31 This data sheet shows...

 Open the catalogue to page 3

Reproduction of this page is strictly prohibited. FLAT COVERS • Standard productsThermic-Welded Cover materials Fabric material code Stiffener materials

 Open the catalogue to page 4

FLAT COVERS • Standard products Standard Shapes NOTE: The above are only the standard shapes of Thermic-Welded Covers. Other shapes available upon request. Flange Fastening Systems Solution with sheet steel, aluminum or PVC flange Shape and holes per customer drawings Reproduction of this page is strictly prohibited. Solution with sheet steel, aluminum or PVC flange Shape and holes per customer drawings Solution with connector flange protruding from the cover profile, made of sheet steel, aluminum or PVC Solution with sheet steel flange Shape and holes per customer drawings Threaded flange holes Type...

 Open the catalogue to page 5

FLAT COVERS • Standard products BELLOWS FOR HOISTING PLATFORM Systems for fastening Bellows for Lift Tables B Solution with sheet steel, aluminum or PVC flange. Shape and holes per customer drawings. Solution with rapid VELCRO connection. This solution offers: • Rapid application and removal of the cover • Low cost Solution with sheet steel, aluminum or PVC flange. Shape and holes per customer drawings. Bellows inner collar. Suitable for screw fastening. Bellows outer collar. Suitable for screw fastening. • Protection of level changing in assembly lines of the manufacturing industry • Base protection...

 Open the catalogue to page 6

FLAT COVERS • Standard products Reproduction of this page is strictly prohibited. BELLOWS FOR LASER AND PLASMA MACHINES

 Open the catalogue to page 7

Solution A: Fastening holdfast Bellows-fastening standard systems for linear slides Solution B: Velcro flange fastening (B1 and B2) Suitable for dry working places ilvvvv Reproduction of this page is strictly prohibited. The "M" zone must be screened with a plate fixed on the table side. Standard flange Type B1 in PVC OOO OOOOOOOOO 0/6 o OOO OOOOOOOO <^6 0 o Standard flange Type B2 in PVC o o o o o o o o o o o o o o o o Pos.1 a) Fix the type 1 standard flange at the head of the slide, b) Fix the bellows to the type 1 standard flange by pressing strongly. Pos.2-3 a) Fix the table or the mounting...

 Open the catalogue to page 8

Example of bellows mounted on linear slides Reproduction of this page is strictly prohibited. List of Standard Material Type of material    Stiffener    Fabric material    G°sed length Standard Thermic-Welded Covers Size Slide nominal    Ply    Bellow    Total    Slide value    height    width    height    deviation NOTE: For the W1 slide over size 65, please contact our Technical Dept. Example of the identification code of a Thermic-Welded Cover for Linear Slides complete with flange Slide manufacturer Slide model Slide nominal value (W1) Open length (stroke + closed length) Type of material Flange...