See other catalogues for
PCBMotor
You may also be interested in
Text version of the page
| | | | | | | | | | | | | | | | | |
| | | |
| | | Life time test Valve Application | | |
| | | |
| | | This test places a PCBMotor 030mm in a Valve application with a measuring gauge. The PCBMotor is activating the valve with a force of 100N via a spindle. The graph shows how long it takes for the motor to activate. The motor stands still for 5 seconds between each activation. \ The test was performed at approx 50% duty cycle to lower the temperature rise due to self heating. | | |
| | | |
| | | Test of PCBMotor | | |
| | | Test setup | | |
| | | |
| | | |
| | | Time: Min; Sec | | |
| | | |
| | | The test lasted 125,000 cycles, corresponding to more than 1000 hours of operation. There were no significant changes to the motor during or after the test. | | |
| | | |
| | | 2008-08-08 ver. 3.1 PCBMOTOR ApS * Krakasvej 17 * DK-3400 Hillerod * Denmark * VAT no. DK30509218 | | |
| | | |
| | | | | | | | | | | | | | | | | |