Text version of the page
Text version of the page
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | ICP® Quartz Force Rings | | | | | | | | | | | | | | | | | | | | | | | | ICP® Quartz Force Rings | | | | | Low Profile | General Purpose | | | | Model Number | Unit | 201A75 | 201A76 | 201B01 | 201B02 | 201B03 | 201B04 | 201B05 | | | | Performance Specifications | | | | | | | | | | Compression Range1" | lb (N) | 5000 (22k) | 5000 (22k) | 10 (45) | 100 (450) | 500 (2200) | 1000 (4500) | 5000 (22k) | | | | Maximum Compression | lb (N) | 5000 (22k) | 5000 (22k) | 60 (270) | 600 (2700) | 3000 (13k) | 6000 (27k) | 8000 (35k) | | | | Voltage Sensitivity (± 15%) | mV/lb (mV/N) | 1 (0.22) | 1 (0.22) | 500 (110) | 50 (11) | 10 (2.2) | 5 (1.1) | 1 (0.22) | | | | Resolution (broadband) | lb rms | 0.10 | 0.10 | 0.0002 | 0.002 | 0.01 | 0.02 | 0.10 | | | | N rms | 0.45 | 0.45 | 0.0009 | 0.009 | 0.045 | 0.09 | 0.45 | | | | Amplitude Linearity161 | % FS | < 1 | < 1 | < 1 | < 1 | < 1 | < 1 | < 1 | | | | Upper Frequency Limit | Hz | 90k | 90k | 90k | 90k | 90k | 90k | 90k | | | | Low Freq. Response (-5%) | Hz | 0.0003 | 0.0003 | 0.01 | 0.001 | 0.0003 | 0.0003 | 0.0003 | | | | Temperature Range | °F | -65 to +250 | -65 to +250 | -65 to +250 | -65 to +250 | -65 to +250 | -65 to +250 | -65 to +250 | | | | °C | -54 to +121 | -54 to +121 | -54 to +121 | -54 to +121 | -54 to +121 | -54 to +121 | -54 to +121 | | | | Temperature Coefficient | %/°F | < 0.03 | < 0.03 | < 0.03 | < 0.03 | < 0.03 | < 0.03 | < 0.03 | | | | %/°C | < 0.054 | < 0.054 | < 0.054 | < 0.054 | < 0.054 | < 0.054 | < 0.054 | | | | Electrical Specifications | | | | | | | | | | Discharge Time Constant121 | second | > 2000 | > 2000 | > 50 | > 500 | > 2000 | > 2000 | > 2000 | | | | Output Impedance | ohm | < 100 | < 100 | < 100 | < 100 | < 100 | < 100 | < 100 | | | | Output Bias Voltage | +VDC | 8 to 14 | 8 to 14 | 8 to 14 | 8 to 14 | 8 to 14 | 8 to 14 | 8 to 14 | | | | Voltage Excitation | +VDC | 20 to 30 | 20 to 30 | 20 to 30 | 20 to 30 | 20 to 30 | 20 to 30 | 20 to 30 | | | | Constant Current Excitation | mA | 2 to 20 | 2 to 20 | 2 to 20 | 2 to 20 | 2 to 20 | 2 to 20 | 2 to 20 | | | | Polarity: Compression | | positive | positive | positive | positive | positive | positive | positive | | | | Physical Specifications | | | | | | | | | | Recommended Pre-load | lb (N) | 1000 (4500) | 1000 (4500) | 60 (267) | 100 (445) | 200 (890) | 400 (1779) | 1000 (4500) | | | | Connector | type | BNC jack | 5-44 coax | 10-32 coax | 10-32 coax | 10-32 coax | 10-32 coax | 10-32 coax | | | | Stiffness | lb/pin (kN/um) | 16 (2.8) | 16 (2.8) | 12 (2.1) | 12 (2.1) | 12 (2.1) | 12 (2.1) | 12 (2.1) | | | | Sealing | type | epoxy | hermetic weld | hermetic weld | hermetic weld | hermetic weld | hermetic weld | hermetic weld | | | | Material (stainless steel) | type | 304L / 17-4 | 304L / 17-4 | 304L / 17-4 | 304L / 17-4 | 304L / 17-4 | 304L / 17-4 | 304L / 17-4 | | | | Weight | oz (gm) | 0.25 (7) | 0.25 (7) | 0.35 (10) | 0.35 (10) | 0.35 (10) | 0.35 (10) | 0.35 (10) | | | | Supplied Accessories13-41 | | | | | | | | | | Mounting Stud | model | 081A11 | 081A11 | 081A11 | 081A11 | 081A11 | 081A11 | 081A11 | | | | Mounting Stud Thread | size | 10-32 | 10-32 | 10-32 | 10-32 | 10-32 | 10-32 | 10-32 | | | | Anti-friction Washer | model | N/A | N/A | 082B01 | 082B01 | 082B01 | 082B01 | 082B01 | | | | Pilot Bushing | model | 083A15 | 083A15 | 083B01 | 083B01 | 083B01 | 083B01 | 083B01 | | | | Options151 | prefix | M,N | M,N,W | M,N,W | M,N,W | M,N,W | M,N,W | M,N,W | | | | | | | | | | | | | | | | | | | | | | | | Notes: [1] 1 lb = 4.448 N (values shown are approximate) [2] The Discharge Time Constant (DTC) determines low frequency response according to the relationship f-5%=3/(2n(DTC)). Sensors accurately follow transient events lasting a few percent of the DTC. For square wave events, the DTC should be 100 times the event duration. For ramp shape events, the DTC should be 50 times the event duration and for a half sine pulse the DTC should be 25 times the pulse duration. To ensure measurement system compatibility, use DC coupled or Long Time Constant signal conditioners for long duration transient measurements. [3] NIST traceable calibration certificate is supplied with each sensor. [4] See page 2.13 for complete accessory listings. [5] See page 1.17 for a description of options (specifications for optional versions may differ slightly. Consult factory before ordering). For complete listing of metric mounting studs and screws, see page 2.23. [6] Recommended pre-load is required to meet published specification and calibration. | | | | | | | | | | ICP® Quartz Force Ring Measurement System | | | | | | | | | | Standard Sensor Cable* | | | | | | □ | | | | | | | | | | Output Cable | | | | | | | | | | O □il | | | | | | | | | | m» la- | | | | | | & & & | | | | | | | | | | | | | | | | | | | | | | | | * Low-noise cables are required to maintain C€ conformance. | | | | | | | | | | Constant Current Signal Conditioner | | | | | | Readout Device | | | | | | | | | | | | | | | | | | 1.27 | | | | | | PCB Piezotronics, Inc. S Toll-Free in USA 888-684-0004 W 71 6-684-0001 ©www.pcb.com | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|