Calibration Test Services and Equipment

Dynamic Strain, Force, and Strain gage Torque & Load Calibrations

PCB

®

offers calibration services for dynamic strain and force sensors, as well as strain gage torque sensors and load cells. Each dynamicstrain or force sensor is provided with a five-point ascending compression calibration. Sensitivity and non-linearity data are reported.Tension calibration may be supplied upon request. Strain gage torque sensors are calibrated in both clockwise and counterclockwisedirections. Strain gage load cells are calibrated in both tension and compression. Sensitivity, non-linearity, hysteresis, and shunt calibrationdata are provided for static sensors.

Dynamic Strain Sensor Calibration Services

â– 

Strain gage reference

â– 

For Series 240 and 740 ICP

®

strain sensors

Dynamic Strain Sensitivity Calibrations
A known strain input is placed on the sensor, and sensitivity measured via reference sensor

Dynamic Force Sensor Calibration Services

â– 

Strain Gage Reference

â–  10 to 100k lb (445 to 450k N range)
Comparison Calibration
â–  1.0 % FS accuracy A large, hydraulic press manufacturer generates compressive loads for reference comparative testing

Torque Sensor Absolute Calibration

â– 

Torque arm method, where known weights are applied from a beam at known distances from the sensor's axis of symmetry

Torque Sensor Absolute Calibration
Otherwise know as a “torque arm”, known weights are suspended from the beam at known distances from the sensor’s axis of symmetry
â–  10 to 25k in-lb (1.10 to 2800 N-m) range 0.04% FS accuracy
â–  25k to 100k in-lb (11,300 to 56,500 N-m) range 0.14% FS accuracy
â–  100k to 300k in-lb (0 to 33,896 N-m) range 0.09% FS accuracy

Static Load Cell Absolute Calibration

â–  Deadweight 10 to 500 lb (45 to 2230 N), 0.04 % FS accuracy
Load Cell Absolute Calibration
Accurate dead weights are utilized for testing against basic physical parameters
â–  Back-to-back to 100 to 10k lb (2230 to 45k N) 0.06% FS accuracy
â–  Back-to-back to 10k to 100k lb (45 to 450k N) 0.08% FS accuracy PCB Piezotronics, Inc. Toll-Freein USA 800-828-8840 716-684-0001 www.pcb.com

43

DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48