You may also be interested in
Geophone, Camera, Analysis software, Temperature indicator, Software
Text version of the page
Combined system 16SG SeriesWhat makes this system really unique is its extreme versatility. Our design philosophy for this realization was in fact characterized by the need to create a system which would not only guarantee important performances and make it easy to use, but which would really be of multipurpose type. The possibility to manage the two different investigation methods – refraction/reflection seismics as well as electrical imaging – through a high-level softwa-re and a hardware characterized by extraordinary performance features, has allowed the realization of a combined modular instrument, which may grow in successive steps, finally offering the opportunity to complete your system base as to your real needsVia Galliari 5/E 10125 Torino - Italy Phone +39 011 6507033 FAX +39 011 658646 info@pasisrl.it www.pasigeophysics.com AVAILABLE MODELS POSSIBLE UPGRADES . Model Code Bit Seismic channels Electrical imaging 16SG24-N SIS-201-000 24* 24 YES 16SG12-N (on request) SIS-200-000 24* 12 YES From Model To Model Bit Seismic channels Electrical imaging 16S24-N 16SG24-N 24* - + 16G-N 16SG24-N 24* +24 - *with oversampling and postprocessing Main functions- seismograph Filter Activation: in acquisition or post-acquisition Antialiasing filters: active, LPF, 8th in Butterworth order; attenuation -48dB/oct (-160dB/dec); f=5/8 fnyq; accuracy. ±1% cutting frequency Enhancement with/without total/partial preview Geophone polarity inversion Marker for the determination of the video points position on the time scale; possibility to save the first arrivals on file for data download to PC A.G.C. Automatic Gain Control Delay: Pre-trigger 0-10ms (step of 1ms); Post-trigger 0-16000ms (step of 1ms) Display in wiggle-trace or variable area Noise-monitor with “real time” cascade display Automatic or manual trace-size for each channel Automatic recording of acquisition Data download to PC via USB Automatic calibrations Data codification in SEG-2 format - electrical imaging: Possibility to record acquisition on internal HD Automatically managed gains in autoranging mode Automatic cleaning of self potentials Automatic calibrations:double offset calibration, input calibration on reference voltages, gain calibration Automatic test procedures for the Link.Box operating ability, the correct connection of electrodes and diagnostics. Management of energizer and polarization reversal from the central processing unit Design of energetic wave Display of GTDT (Ground Time Domain Test) for a correct programming of wave COUPLING function for the check of spreading electrodes ROLL-ALONG for the realization of continuous profiles with a minimum of 32 elec-trodes Linear and logarithmic PSEUDOSECTION |
|