| Recommendation for filtration Class 21/18/14, according to ISO 4406 21 = 10000 to 20000 particle > 4um per ml fluid 18 = 1300 to 2500 particle > 6um per ml fluid 14 = 80 to 160 particle > 14um per ml fluid Seals Check hydraulic fluid specification for chemical resistance of seal material. Check temperature range of seal material and compare with max. system and ambient temperature. D - Nitrile, double shaft seal -40 ... +90 °C V - Fluorocarbon, single shaft seal -15 ... +150 °C T - Fluorocarbon, double shaft seal -15 ... +150 °C Note: The highest fluid temperature will be at the drain port of the pump, up to 20°C higher than in the reservoir. |