Variable Displacement Piston pump specification Series P2
Catalogue HY11-2601/UK
Technical Information
Technical Features
• Compact design
• Low noise level
• Service-friendly
• Reliable
• Long-lasting
• Flexible
• Easy to install
• High self-priming speed
Technical Data
Frame size
P2060
P2075
P2105
P2145
Max. displacement
[cm3/rev]
60
75
105
145
Self-priming speed at 1 bar absolute inlet pressure
[rpm]
2800
2500
2300
2200
Max. continuous pressure
[bar]
320
320
320
320
Peak pressure
[bar]
370
370
370
370
Min. inlet pressure absolute
[bar]
0.8
0.8
0.8
0.8
at max. speed
[in Hg vacuum]
5.8
5.8
5.8
5.8
Max. inlet pressure
[bar]
10
10
10
10
Max. case industrial drain pressure
[bar]
0.5
0.5
0.5
0.5
Noise level at full flow at 1800 rpm and 250 bar
[dbA]
74
76
78
80
Weight with load sense control
[kg]
37
44
63
78
Mass moment of inertia (at axis of shaft)
[kg m2]
0.0061
0.0101
0.0168
0.0241
General information Fluid recommendations
• Normal mineral oil
• Premium hydraulic fluid / HLP oil
• Synthetic hydraulic ester
• Fire resistant fluids, water based (HFC)
Note: Maximum system pressure reduced to 210 bar for water based fluids. Bearing manufacturer life time reduced to 25% by using water based fluids.
Viscosity
Min. viscosity for short periods: 10 mm2/s (cSt) Normal operating viscosity: 15...40 mm2/s (cSt)
Max. viscosity for short periods: 1000 mm2/s (cSt)
Filtration
For maximum pump supplier and system component functionability and life, the system should be protected from contamina­tion by effective filtration.
Fluid cleanliness should be in accordance with ISO classification ISO 4406. The quality of filter elements should be in accordance with ISO standards.
PI HY11-2601UK.PMD RH
Recommendation for filtration
Class 21/18/14, according to ISO 4406
21 = 10000 to 20000 particle > 4um per ml fluid 18 = 1300 to 2500 particle > 6um per ml fluid 14 = 80 to 160 particle > 14um per ml fluid
Seals
Check hydraulic fluid specification for chemical resis­tance of seal material.
Check temperature range of seal material and compare with max. system and ambient temperature.
N - Nitrile, single shaft sealing -40 ... +90 °C
D - Nitrile, double shaft seal -40 ... +90 °C
V - Fluorocarbon, single shaft seal -15 ... +150 °C T - Fluorocarbon, double shaft seal -15 ... +150 °C Note: The highest fluid temperature will be at the drain port of the pump, up to 20°C higher than in the reservoir.
Parker Hannifin GmbH
Hydraulic Controls Division Kaarst, Germany
3
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
pdf-page pdf di En 2010-03-11-17