Catalogue Hydraulic Motors
www.parker.com
print switch display
Page / 68
Where to buy
this product ?
Request
a Quote
PARKER Hydraulics - 68442, 80669, 6314
/ 68
See other catalogues for PARKER Hydraulics
Text version of the page
Catalogue HY17-8223/UK

Industrial hydraulic motors Technical Information Series V12 EO two-position control

The EO is a two-position control, where max and min dis-placements are governed by a DC solenoid attached to the control cover (refer to the installation drawing on page 27).The EO control is utilized in transmissions where onlytwo operating modes are required: Low speed/high torque or high speed/low torque.The servo piston, normally in the max displacementposition, shifts to the min displacement position when the solenoid is activated. Intermediate displacements cannot be obtained with this control.Servo pressure is supplied internally (through the shuttlevalve from one of the main high pressure ports) or exter- nally (port X4).The solenoid is either 12 or 24 VDC, requiring 1.2 and0.6 A respectively. An industrial electrical connector is included (DIN 43650/IP54).The EO two-position control is available in four versions:
Displacement(setting piston position) SolenoidcurrentI Max EOH 01 I -Internal servo supply, 24 VDC EOL 01 I -Internal servo supply, 12 VDC

2

EOH 01 E -External servo supply, 24 VDC(optional) EOL 01 E -External servo supply, 12 VDC(optional)Gauge ports (EO control):X1Setting piston pressure (max-to-min) X2Servo supply pressure (after orifice) X4Servo supply pressure (before orifice) X6Setting piston pressure (min-to-max)Ports are:–M14x1.5 (ISO and cartridge versions) –
Min X4X2 s Thresholdcurrent EO diagram. EO H 01 I schematic (non-activated solenoid).
X4X2 A MaxMin X6X1 B A 9 /
16 "-18 O-ring boss (SAE version).
MaxMin X6X1 B EO H 01 E schematic (non-activated solenoid). 23
Parker Hannifin Mobile Controls DivisionTrollhättan, Sweden
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1-50
51-68
pdf-page pdf di En 2008-12-49-05