cad

Parker Legris - Adjustable Check Valves in Nickel-Plated Brass
4Pages

{{requestButtons}}

Catalog excerpts

Parker Legris - Adjustable Check Valves in Nickel-Plated Brass - 1

Adjustable Check Valves Designed for Compressed Air Applications climate control process control sealing & shielding ENGINEERING YOUR SUCCESS.

Open the catalog to page 1
Parker Legris - Adjustable Check Valves in Nickel-Plated Brass - 2

Low Pressure ADJUSTABLE CHECK VALVES Food Process Machine Tools Printing Machines Textile Machines Chemical/Petrochemical In-Plant Automotive Non-Return Valve Function • Allows air to pass in one direction whilst blocking flow in the other direction • May be mounted upstream of the circuit Perfectly Designed for Use in Severe Environments • Excellent resistance to abrasion and corrosion • Compatible with industrial food applications, in conformity with FDA and 1935/2004 standards Optimized Inventory Management • Reduction of part numbers stocked thanks to integrated function for opening...

Open the catalog to page 2
Parker Legris - Adjustable Check Valves in Nickel-Plated Brass - 3

Technical Characteristics Constituent Materials Check valve: chemica nickel-plated brass nickel-plated brass Suitable Fluid Working Pressure stainless stee nickel-plated brass ^-Working Pressure > Maximum Tightening Torque > Cracking Pressure Setting * Working Principle Turn the locking nut with an Allen key Turn the setting nut with a smaller Allen key to adjust The number of turns sets the cracking pressure Turn the locking nut with an Allen key to lock the cracking pressure setting. Then control the pressure with a pressure gauge downstream

Open the catalog to page 3
Parker Legris - Adjustable Check Valves in Nickel-Plated Brass - 4

7930 Adjustable check valve double female, BSPP and metric thread 7931 Adjustable check valve male-female, supply version, BSPP thread 7932 Adjustable check valve male-female, exhaust version, BSPP thread BSPT supply and exhaust versions are also available upon request for diameters R1/8, R1/4, R3/8 and R1/2. The nickel-plated brass check valve can come Into direct contact with food, but Is not suitable for oermanent food contact According to the FDA standard and 1935/2004 regulation, the minimum flow outside the product must Darker Legris has a policy of continual product development and...

Open the catalog to page 4