catalogue search
|
You may also be interested in
Valve, Pressure regulator, Cylinder, Rodless actuator, Damper
Text version of the page
Characteristics Symbol Unit Description Actuation Pneumatic Direct - actuation pressure range - permanent signal version pst min./max. bar 2 - 8 (5/2 way version), 3 - 8 (5/3 and 2x3/2 way version) - impulse version pst min./max. bar 1.5 - 8 (5/2 way version) Electrical single Valves S10 Electrically pilot actuated Voltage types Alternating current (50/60Hz) Direct current Nominal voltage - standard version Un V 230, 110, 48 ±10% 24, 12 ±10% other voltages available on request Power consumption, switching - standard version VA (W) ca. 2.8 1.1 Power consumption, holding - standard version VA (W) ca. 2 1.1 Duty cycle ED % 100 Electrical protection IP IP 65 to DIN 40050 (applise only to solenoid with plug) Connection Connector to DIN EN 175301-803 form C (1 Electrical valve islands IM10 Electrically pilot actuated Nominal voltage Un V 24, 12 Voltage types Direct current Power consumption, switching VA (W) 1.1 Power consumption, holding VA (W) 1.1 Duty cycle ED % 100 Electrical protection IP IP 65 to DIN 40050 (Applise only to the electrically part in combination with sub-D connector, IP 65) Connection D-Sub connector 25pin Switching indicator LED Number of outputs max. 22, max. 18 (monostable) (1 Solenoid also available with cable (length 1m) - see Order Instructions 17
|