Catalogue MX80 miniature stage series
www.parkermotion.com
print switch display
Page / 33
Parker Electromechanical Automation - 314117, 92840
/ 33
See other catalogues for Parker Electromechanical Automation
Text version of the page
Catalog 8092/USA
Miniature Stages
MX80L Miniature Manufacturer of linear motor Stage
Specifications: How we measure accuracy:
All published linear table accuracy and repeatability specifications vary according to testing and reporting methodology. Parker methodology includes data reporting over the entire table travel length, regardless of the start or stop position.
Testing is performed with the table unloaded and mount­ed to a stable granite surface, at 20o C. Accuracy and repeatability specifications are based on a peak to peak range of error, measured by a laser interferometer with the beam located 35mm above the center of the table top. The reported error totals six degrees of freedom (x,y,z, plus roll, pitch and yaw errors). Final table specifications are established from the maximum positive (+) error to the maximum negative (-) error.
30
p - n i- fxm Tr
rcok ( 1 UO, 1 U
-
Peak (TU1,TU
2)
Continuous (T
"03,T04)
Continuous (
"01,102
____
1,000,000
25
20
E
Z
100,000
15
0J
G O LL
10
5
10,000
0
1 2 3 4 5 6 7 8
Load (kg)
0
0
400
800
1200
1600
2000
Speed mm/second
Note: T01(25mm travel) is limited to a maximum speed of 1100 mm/sec. T02 (50mm) is limited to 1500. (due to limited travel)
Life- Load (Normal load)
Force - Speed
Parker Hannifin Corporation Electromechanical Automation Division Irwin, Pennsylvania
^35
www.parkermotion.com
C10
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33