| | | HD Series - Engineering Reference | | |
| | | |
| | | The following performance information is provided as a supplement to the product specifications pages. The following graphs are used to establish the table life relative to the applied loads. The useful life of a linear table at full catalog specifications is dependent on the forces acting upon it. These forces include both static components resulting from payload weight, and dynamic components due to acceleration/deceleration of the load. In multi-axes applications, the primary positioner at the bottom of the stack usually establishes the load limits for the combined axes. When determining life/load, it is critical to include the weight of all positioning elements that contribute to the load supported by the primary axis. | | |
| | | |
| | | Table Life/Load Chart Compression (normal load) | | |
| | | |
| | | Life with Compression Load | | |
| | | |
| | | 100000 | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | HD085 HD125 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | 1 | | | | | | | | | | | | | | | | — HD185 | | | | | | | | | | | | | | | | | | | | | | | | | | | | \ | | | | | | | | | | | | | | | | | | | | | | | \ | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | \ | | | | | | | | | | | | | | | | | | | | | | | \ | | | | | | | | | | | | | | | | | | | | | | | \ | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | |
| | | This graph provides evaluation of the support bearing suppliers life/load characteristics. The curves show the life/load relationship when the applied load is centered on the carriage, normal (perpendicular) to the carriage mounting surface. For final evaluation of life vs load, including off center, tension, and side loads refer to the charts and formulas found at www.parkermotion.com. | | |
| | | 10000 | | |
| | | |
| | | |
| | | 1000 | | |
| | | |
| | | |
| | | 0 | | 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 Load (N) | | |
| | | |
| | | |
| | | www.parkermotion.con | | |
| | | Parker Hannifin Corporation Electromechanical Automation Division Irwin, Pennsylvania | | |
| | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |