Analytical Gas Systems
52Pages

{{requestButtons}}

Catalog excerpts

Analytical Gas Systems - 1

climate control process control sealing & shielding ENGINEERING YOUR SUCCESS.

Open the catalog to page 1
Analytical Gas Systems - 2

Parker domnick hunter Parker domnick hunter is the leading provider of Gas Systems for the Analytical Instrument market. Generators are specifically designed to meet the stringent gas requirements for all the leading Analytical Instrument manufacturers including Agilent, Thermo Fisher, Waters, Shimadzu, AB Sciex, Perkin Elmer and many others. Utilising Parker's range of patented proprietary technologies, there are 1,000's of systems installed worldwide. These technologies offersome unique performance benefits, including guaranteed ultra high purity gas, silent operation, minimal moving...

Open the catalog to page 2
Analytical Gas Systems - 3

common sight in many laboratories: a default for supplying analytical instruments with their gas requirements, high-pressure gas cylinders are familiar and provide the gas that's required, so it could be said that the old adage, 'if it isn't broke, don't fix it,' could well apply. Despite this, increasing numbers of analytical instrument users are choosing to supply their GC FID, LC/MS and other types of instrument with gas via an analytical gas generator. Driving this decision will be a combination of factors broadly grouped into four areas; safety, cost, convenience and purity. Safety...

Open the catalog to page 3
Analytical Gas Systems - 4

re-calibration, are required before samples can be run. Life is more convenient with a gas generator as there's no unplanned downtime. Analytical gas generators only require simple quick maintenance which can be planned for - they don't unexpectedly run-out of gas halfway through analysis. Increased Purity... Analytical gas generators provide a constant source of gas. This removes the variations in purity between cylinders, helping to improve sensitive analyses. Purity is also preserved because there is no chance for impurities to enter the gas pipes, which may happen as cylinders are...

Open the catalog to page 4
Analytical Gas Systems - 7

Product Information Sheet Hydrogen Generators for GC combustion detector applications The Parker domnick hunter H high purity hydrogen gas generators offer the optimum combination of safe operation, reliability and performance. Utilising field proven PEM cell technology hydrogen is produced on demand from deionised water and electricity, at low pressure and with minimal stored volume. Innovative control software allows unrivalled operational safety and reliability. The H generators ideally supply fuel gas to all known GC combustion detectors used in today's laboratory workflows. Three...

Open the catalog to page 7
Analytical Gas Systems - 8

Product Selection 'With respect to oxygen Note: For auto water fill option add suffix AWF ie 20H-AWF Technical Data Preventative Maintenance * 20H Continuous operation approx 6 to 7 months * 40H Continuous operation approx 4 to 5 months * 60H Continuous operation approx 2 to 3 months Optional Extra's ©2011 Parker Hannifin Corporation. All rights reserved. Catalogue: 174004749J)1_EN 03/11 ENGINEERING YOUR SUCCESS.

Open the catalog to page 8
Analytical Gas Systems - 9

Product Information Sheet Hydrogen Generators for GC and GC/MS carrier gas applications The Parker domnick hunter H-MD ultra high purity hydrogen gas generators offer the optimum combination of safe operation, reliability, performance and low cost of ownership. Utilising field proven PEM cell technology hydrogen is produced on demand from deionised water and electricity, at low pressure and with minimal stored volume. Innovative control software allows unrivalled operational safety and reliability. The H-MD generators ideally supply GC and GC/MS carrier gas, in addition to all known...

Open the catalog to page 9
Analytical Gas Systems - 10

Product Selection 'With respect to oxygen Note: For auto water fill option add suffix AWF ie 20H-MD-AWF Technical Data Preventative Maintenance Optional Extra's ©2011 Parker Hannifin Corporation. All rights reserved. Catalogue: 174004750_01_EN 03/11

Open the catalog to page 10
Analytical Gas Systems - 11

ENGINEERING YOUR SUCCESS. The Analysis of 16 EPA PAHs by GC/MS using Mark Wilkinson (mark.wilkinson@parker.com), James Heseltine (james.heseltine@parker.com) The aim of this technical paper is to optimize and produce a robust and repeatable method for the analysis of 16 EPA PAHs by GC/MS using generated hydrogen carrier gas, over helium. This yields vastly improved analytical performance with shortened run times, whilst eliminating laboratory hazards associated with high pressure vessel usage, storage and handling. Hydrogen is the choice of carrier gas for many applications, due to faster...

Open the catalog to page 11
Analytical Gas Systems - 12

Detection limits of lppb were easily achieved, with excellent baseline resolution. 10 replicates were ran at this level, with typical RSD's of <0.1, and signal/noise (s/n) ratios varying between 5 and 20 (typically <10). Standards were prepared in Dichloromethane over a range of 5 to lOOppb. Calibration over this range showed excellent linearity with all compounds Late compound tailing - Helium Elimination of peak tailing ■ Typically, late eluting PAHs tend to tail, sometimes quite badly, making integration difficult, and peak asymmetry poor. In the above example, you can see clearly that...

Open the catalog to page 12
Analytical Gas Systems - 13

Product Information Sheet Hydrogen Generators The Parker domnick hunter 40H-ICP hydrogen gas generator, developed in collaboration with major instrument vendors, meets the initial purge and reaction gas requirements of the Collision Reaction Interface, providing simple routine removal of troublesome spectroscopic indifferences. Utilising field proven PEM cell technology, hydrogen is produced on demand from deionised water and electricity, at low pressure and with minimal stored volume. Innovative control software allows unrivalled operational safety and reliability. The 40H-ICP hydrogen...

Open the catalog to page 13
Analytical Gas Systems - 14

PrOdllCt Selection Note: For auto water fill option add suffix AWF ie 20H-AWF 'With respect to oxygen Note: For auto water fill option add suffix AWF ie 40H-ICP-AWF Technical Data Preventative Maintenance ©2011 Parker Hannifin Corporation. All rights reserved. Catalogue: 174004751_01_EN 03/11 ENGINEERING YOUR SUCCESS.

Open the catalog to page 14
Analytical Gas Systems - 15

Product Information Sheet for GC combustion detector applications The Parker domnick hunter UHP-ZA zero air generators produce a continuous stream of organic impurity free air from an external dry compressed air source and offer superior limits of detection over and above other modes of supply. Flow rates range from 1 LVmin to 30 LVmin. The UHP-ZA generators feature an interchangeable top panel facilitating the direct mounting of any Parker domnick hunter hydrogen generator. The stackable system forms an innovative, modular FID gas station suitable for all known GC combustion UHP-ZA...

Open the catalog to page 15