Text version of the page
192-062011 N6
Direct Drive Servo motors
Motor type 500STK
Natural convection
Fluid cooling
K
AF
uj|
500STK1M
500STK2M
500STK3M
500STK4M
500STK6M
Housing internal centering diameter
A H8
470
470
470
470
470
Angle cable output / tapped holes
AF
15°
15°
15°
15°
15°
Housing external centering diameter (fluid cooling)
B f8
502
502
502
502
502
Housing external centering diameter (natural convection)
B f8
502
502
502
502
502
Rotor internal centering diameter
C H7
350
350
350
350
350
Housing internal diameter
De
403
403
403
403
403
Depth of fluid front input / output groove
E1
5
5
5
5
5
Width of fluid front input / output groove
E2
18.95
18.95
18.95
18.95
18.95
Position of fluid front input / output groove
E3
23.2 (63.2)
23.2 (63.2)
23.2 (63.2)
23.2 (63.2)
23.2 (63.2)
Rotor fixing holes
FR
12xM8 on 0364
12xM8 on 0364
12xM8 on 0364
12xM8 on 0364
12xM8 on 0364
Housing fixing holes
FS
12xM8 on 0482
12xM8 on 0482
12xM8 on 0482
12xM8 on 0482
12xM8 on 0482
O-ring groove depth
J1
3.4
3.4
3.4
3.4
3.4
O-ring groove width
J2
5.2
5.2
5.2
5.2
5.2
Position of rear o-ring groove
J3
9
9
9
9
9
Position of front o-ring groove
J4
14 (54)
14 (54)
14 (54)
14 (54)
14 (54)
Depth of housing internal centering diameter
LA
3
3
3
3
3
Housing length
LB
93 (133)
120.5 (160.5)
148 (188)
175.5 (215.5)
230.5 (270.5)
Alignment rotor / housing
P ± 0.1
37 (77)
37 (77)
37 (77)
37 (77)
37 (77)
Maximum rotor contact diameter
Pmax
384
384
384
384
284
Rotor length
R +0.15
27.5
55
82.5
110
165
Depth of fluid rear input / output groove
S1
5
5
5
5
5
Width of fluid rear input / output groove
S2
18.9
18.9
18.9
18.9
18.9
Position of fluid rear input / output groove
S3
18.2
18.2
18.2
18.2
18.2
Air gap
mm
0.8
APPLICATION NOTES :
</ The cables are made of PU, class 6, suitable for cable-guiding industrial chains, 2m standard length, copper X-sectlon area according to rated current.
</ Rotor/housing alignment (P) must be accurate to within +/- 0.1 mm. Optionally, we can supply a mounting tool for achieving this alignment when assembly
without accurate alignment is impossible. </ Thermal device cable consists of a shielded pair 2x0.14mm2 section, 4mm external diameter. </ (De) represents: 1- The maximum diameter passing inside the housing.
2- The maximum diameter necessary for rotor assembly. </ (Pmax) diameter for components in contact with the rotor must never be exceeded. </ Tapped holes on each side of rotor and housing are angularly aligned.
</ Cable positioning (AF) is theoretical. Leave a free area with a +/- 10 degree tolerance around this position, at a 30 mm height from the side of the housing, to
avoid applying excessive force to the motor cables. </ When designing the assembly, take care to ensure perfect contact between the housing and user's bore to avoid thermal problems. </ For mounting the housing, use either external the centering diameter (B) or internal centering diameters (A). </ For assembly tolerances (perpendicularity, concentricity...), please consult us. </ Fluid input and output pipes must be aligned with the cable output. </ O-ring grooves are designed for 4 mm diameter o-rings
</ Dimensions in brackets ( ) for P, LB, J4 and E3 are 40mm wider when the nominal current is greater than 72A (4 single wire outputs).
20
Parker Hannifin GmbH & Co. KG
Electromechanical Automation
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
pdf-page pdf di En 2008-12-49-02