192-580011N7
General
By using a linear encoder the static position stiffness of the linear actuator increases, as well as its controllability and positioning accuracy. The static position stiffness describes the ability to retain the current position permanently even if an external force (such as a machining force) is applied. Due to the sensor is mounted on the load attachment plate an additional cable carrier is to be fitted -> see page 28. Attention! The sensor cable is not applicable to be mounted into in cable carriers chain.
If not otherweise specified, the linear encoder is mounted on the same side as the motor. Otherwise please specify with your order "linear encoder right" or "linear encoder left" (see figure below).
Technical data of magnet sensor MSK500 (incremental) (Art.-No.: 035-400014)
Feature
Technical data
Feature
Technical data
Supply voltage
24V DC ± 20%
Output signals
A, /A, B, /B,
Connection / cable length
2m cable, flying leads
Gap magnetic band / sensor
0.1 - 2.0mm
Output circuit
LD Line Driver (RS422)
System accuracy
± (0.025 + 0.01 x L)
(Sensor system!)
mm (L in m)
Reference signal
without
Interference protection class
3, according to IEC 801
Resolution
0.01mm
Temperature ranges
-10°Cto + 70°C
Pulse interval
1us
Protection class
IP67 according to DIN
40050 (housing)
Maximum travel speed10
6.9m/s
Material housing / cable
black plastic/PUR
Power consumption
max. 70mA
Technical Data magnetic band MB500 (Art. No.: 035-400015)
Feature
Technical data
Feature
Technical data
Length
Specify desired length
Reference point
without
(Standard: length = length of HPLA profile)
Width
10mm
Temperature coefficient
(11±1) um/K
Thickness
1.7mm
Temperature ranges
-10°Cto + 70°C
Accuracy class
0.1
Assembly
bond
Cover strip
with cover strip
Compliance
CE
10 The travel speed results from the selected pulse and the corresponding resolution.
34 Parker Hannifin GmbH
Electromechanical Automation
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
pdf-page pdf di En 2008-12-49-02