| | Part Number | Part Description | Std. Pkg. Qty. | Std. Ctn. Qty. | |
| | Optimized 10Gig™ 50/125um (OM3) Multimode Pre-Terminated MTP* Cassettes | |
| | FCXO-12-10Y | Six LC duplex adapters to one male MTP*; 12-fiber optimized pre-terminated MTP* cassette provides low insertion loss of 0.5dB max. per fiber; 10 GbE 50/125um (OM3) fiber. | 1 | | |
| | FCXO-24-10Y | Twelve LC duplex adapters to two male MTPs*; 24-fiber optimized pre-terminated MTP* cassette provides low insertion loss of 0.5dB max. per fiber; 10 GbE 50/125um (OM3) fiber. | 1 | 10 | |
| | FCXO-12-3Y | Six SC duplex adapters to one male MTP*; 12-fiber optimized pre-terminated MTP* cassette provides low insertion loss of 0.5dB max. per fiber; 10 GbE 50/125um (OM3) fiber. | 1 | 10 | |
| | 10Gig™ 50/125um (OM3) Multimode Pre-Terminated MTP* Cassettes | |
| | FCX-12-10Y | Six LC duplex adapters to one male MTP*; 12-fiber pre-terminated MTP* cassette provides low insertion loss of 1.0dB max. per fiber; 10 GbE 50/125um (OM3) fiber. | 1 | 10 | |
| | FCX-24-10Y | Twelve LC duplex adapters to two male MTPs*; 24-fiber pre-terminated MTP* cassette provides low insertion loss of 1.0dB max. per fiber; 10 GbE 50/125um (OM3) fiber. | 1 | 10 | |
| | FCX-12-3SY | Twelve SC simplex adapters to one male MTP*; 12-fiber pre-terminated MTP* cassette provides low insertion loss of 1.0dB max. per fiber; 10 GbE 50/125um (OM3) fiber. | 1 | 10 | |
| | FCX-12-3Y | Six SC duplex adapters to one male MTP*; 12-fiber pre-terminated MTP* cassette provides low insertion loss of 1.0dB max. per fiber; 10 GbE 50/125um (OM3) fiber. | 1 | 10 | |
| | 50/125um (OM2) Multimode Pre-Terminated MTP* Cassettes | |
| | FC5-12-10Y | Six LC duplex adapters to one male MTP*; 12-fiber pre-terminated MTP* cassette provides low insertion loss of 1.0dB max. per fiber; 50/125um (OM2) fiber. | 1 | 10 | |
| | FC5-24-10Y | Twelve LC duplex adapters to two male MTPs*; 24-fiber pre-terminated MTP* cassette provides low insertion loss of 1.0dB max. per fiber; 50/125um (OM2) fiber. | 1 | 10 | |
| | FC5-12-3SY | Twelve SC simplex adapters to one male MTP*; 12-fiber pre-terminated MTP* cassette provides low insertion loss of 1.0dB max. per fiber; 50/125um (OM2) fiber. | 1 | 10 | |
| | FC5-12-3Y | Six SC duplex adapters to one male MTP*; 12-fiber pre-terminated MTP* cassette provides low insertion loss of 1.0dB max. per fiber; 50/125um (OM2) fiber. | 1 | 10 | |
| | 62.5/125um (OM1) Multimode Pre-Terminated MTP* Cassettes | |
| | FC6-12-10Y | Six LC duplex adapters to one male MTP*; 12-fiber pre-terminated MTP* cassette provides low insertion loss of 1.0dB max. per fiber; 62.5/125um (OM1) fiber. | 1 | 10 | |
| | FC6-24-10Y | Twelve LC duplex adapters to two male MTPs*; 24-fiber pre-terminated MTP* cassette provides low insertion loss of 1.0dB max. per fiber; 62.5/125um (OM1) fiber. | 1 | 10 | |
| | FC6-12-3SY | Twelve SC simplex adapters to one male MTP*; 12-fiber pre-terminated MTP* cassette provides low insertion loss of 1.0dB max. per fiber; 62.5/125um (OM1) fiber. | 1 | 10 | |
| | FC6-12-3Y | Six SC duplex adapters to one male MTP*; 12-fiber pre-terminated MTP* cassette provides low insertion loss of 1.0dB max. per fiber; 62.5/125um (OM1) fiber. | 1 | 10 | |
| | For MTP* Connector Cleaning Tools, see page C2.24. *MTP is a registered trademark of US Conec Ltd. Table continued on page C2.34 | |
| | | | | | |