A. System Overview
Pan-Net® NETWORK SOLUTIONS
B1.Cable
TX6™ 10Gia" Shielded Cable
• Exceeds draft requirements of TIA/EIA-568-B.2-AD10 and ISO 11801 Class EA Edition 2.1, and IEEE 802.3an-2006 ratified standard channel requirements for
supporting 10GBASE-T
• Conductors are tightly twisted in pairs and all four pairs are individually wrapped in foil (U/FTP)
• Internal drain wire facilitates grounding
• Maximum installation tension of 25 lbs. (110 N)
B2.Modules
Installation temperature range: 32°F to 140°F (0°C to 60°C)
Operating temperature range: 14°F to 140°F (-10°C to 60°C)
Cable supplied on reel
Descending markings on cable to ease installation Plenum (CMP) and non-plenum/riser (CMR) Third party tested to 650 MHz
B3.Work Area Outlet
Solutions
B4.Surface Raceway
Part Number
Part Description
Colore
Std. Pkg. Qty (Ft.).
Std.
Ctn. Qty.
(Ft.)
Riser
PSR6004BU-UGY
Category 6A riser (CMR) shielded cable. Conductors are 23 AWG construction. Each pair has a metallic foil shield and conductors are protected in a flame-retardant PVC jacket.
Blue
1000
15000
Plenum
PSP6004BU-UGY
Category 6A plenum (CMP) shielded cable. Conductors are 23 aWg construction. Each pair has a metallic foil shield and conductors are protected in a flame-retardant PVC jacket.
Blue
1000
15000
B5.Zone Cabling
Systems
B6.Wireless Solutions
C1. Copper Patch Panels,
Cords &
Punchdowns
C2. Fiber Connectors, Enclosures &
Patch Cords
t For other colors replace BU (Blue) with WH (White), YL (Yellow), or IG (International Gray).
Must be installed as part of a complete 7X6™ 10Gig ™ Copper Cabling System in order to achieve 10GBASE-T
certified performance.
In data center and telecommunication room applications, panduit recommends that both-ends of shielded cable link be bonded if the channel is contained in the same building and any multiple serving AC power systems are intersystem bonded. For workstation applications, it is recommended that the cable link be bonded through the normal process in the telecommunication room and through the patch cord at the workstation, which provides the proper path to ground via the computer's AC power plug.
C3. Overhead & Underfloor Routing Systems
C4. Cabinets, Racks & Cable Management
C5. Grounding & Bonding
D. Managed System Solutions
Cable Labels for TX6 10Gig™ Shielded Cable
E. Industrial
F1. Labeling
&
Identification
Suggested Label Solutions for TIA/EIA-606-A Compliance
Cable Part Number
Laser/Ink Jet Desktop Printer Label
TDP43MY Thermal Transfer Desktop Printer Label
PanTher™ LS8E Hand-Held Printer Label
Cougar™ LS9 Hand-Held Printer Label
PSR6004**-UGY PSP6004**-UGY
S100X225YAJ
S100X225VATY
S100X225VAC
T100X000CBC-BK
F2.Wiring Duct
F3. Cable
Ties&
Accessories
For complete labeling solutions and product information, reference charts on pages F1.5 - F1.12.
G. Index
For service and technical support, call 800-777-3300 (outside the U.S. and Canada, see back cover).