Catalogue Easy User Guide 'Size Measurement'
www.mew-europe.com
print switch display
Page / 5
Panasonic - Matsushita Electric Works - 208296
/ 5
See other catalogues for Panasonic - Matsushita Electric Works
Text version of the page
For in-depth information on carrying out the basic settings in the environmental configuration mode refer to the "Basic Settings" sheet at the end of this "Easy User Guide".

LightPix AE10

The functionality of the MODE button and the SET button is the same for every software package.

EASY USER GUIDE "SIZE MEASUREMENT"

This guide provides an example that leads you from the startup to a functioning application. Besides, you learn about the basic functions of your LightPix. Depending on your experience, you need between 30 and 60 minutes to work through the example. The following diagram shows where the operation buttons are located on the operation unit and which functions the operation buttons have: Working with the operation buttons

!

Please note the safety instructions in your manual and the "NAiS LightPix AE10" leaflet.

Installation

For the following examples you need a finder unit, an operation unit, a main unit and cables. For an explanation of system components, part names and dimensions, refer to the "NAiS LightPix AE10" leaflet included in the package. For in-depth information, refer to your manual. 1. Assemble the LightPix according to the leaflet 1. MODE 2. Connect the power cable by soldering the wires to the connectors Figure 2: Operation buttons diagram For an overview of the MODE button, see Figure 1 For procedure and pin assignment, see the leaflet. 2. SET 3. Mount the main unit at the correct distance from the target object 3. PRMT (Parameters) For an overview of the SET mode, see Figure 1 For the correct distance, refer to the table in the leaflet. Switch the setting items when you are in SET mode or when setting upper/lower limits. In TEACH mode the buttons move the checker size/shape in X-direction (see also Figure 3 ).

Basic Concepts of the LightPix

Your LightPix is delivered with one of the following four software packages: 4. TYPE Color Extraction (Product number: ANE10x0) You can choose from 7 different sets of parameters ("Teachings"). TYPE selects these "Teachings" in RUN mode and switches between exposure time, checker size and checker move in TEACH mode. Press the TYPE button and keep the SET button pressed at the same time to switch types ("Teachings") in TEACH mode. For this example you do not need to do this. Edge Detection (Product number: ANE10x1) Size Measurement (Product number: ANE10x2) Matching (Product number: ANE10x3) This "Easy User Guide" is for the "Size Measurement" software package . Working with the operation modes You can adjust the checker size in TEACH mode for all software packages with the TYPE, PRMT, UP/DOWN buttons. (Checker size = selected area in the field of view to be analyzed The LightPix possesses different operation modes. To switch between them, press the MODE or SET button of your operation unit for 3s or 1s: field of view = maximum area to be analyzed).
Teaching Mode C. TOLERANCE RANGE

Type number

MODE 3s MODE 1s Power ON SET 3s D. INSPECTION Inspection Modes B. IMAGE CAPTURING/TEACHING RUN Mode V IEW Mode - High-speed inspection - No image on finder unit's screen - Inspection 300ms slower - Image on finder unit’s screen RUN- Figure 3: PRMT, TYPE and TRIGGER buttons 5. TRIGGER RUN/RUN-VIEW mode: Executes one inspection TEACH mode: Executes teaching (see also
MODE 1s Figure 3)
SET 1s SET 1s 6. UP/DOWN Change a tolerance value or a setting value in the SET mode.
A. BASIC SETTINGS Environmental Configuration Mode SET Mode SET 1s

Meaning of the tolerance valueType number New tolerance value Previous tolerance

Figure 4: UP/DOWN buttons Figure 1: Operation mode diagram Notes: General rule to exit a mode: Press the same button you pressed to enter the mode for 1s.