operation unit (see also Figure 9).
11. Press the MODE button to return to the inspection mode
12. Test the "OK Rectangle" and the "NG Rectangle" (see example illustrations sheet)
13. Write down the indicated [X] and [Y] coordinates
The intersecting lines are displayed in white. The calculated X/Y coordinate is at the point of intersection (see also Figure 18). Press the UP/DOWN buttons to see the X and the Y coordinate.
C. Set the TOLERANCE RANGE
There are four parameters in the tolerance range SET mode:
• [rEFX], [rEFY]: The reference values for the X and the Y coordinate were registered when you taught the position in step 3 of the "B. TEACHING" procedure. Therefore they cannot be changed.
• [PErX], [PErY]: You can change the allowed tolerance in X and in Y direction using the UP/DOWN buttons (see also Figure 16 and 17).
2. Check the results displayed on the operation unit and on the finder unit's screen
-X/Y edge direction
-X/Y value, measured in mm
Figure 18: Edge detection inspection The intersecting lines are displayed in white. The calculated X/Y coordinate is at the point of intersection. Press the UP/DOWN buttons to see the X and the Y coordinate. For in-depth procedures, refer to your LightPix manual.
1.
Press the SET button shortly
2. Press the PRMT buttons to check [rEFX] and [rEFY] for the selected type
Select the same type you used in TEACH mode.
Figure 14: Reference coordinates [rEFX] and [rEFY]
Press the PRMT buttons to define [PErX] and [PErY] for the
selected type
Select the same type you used in TEACH mode.
3.
Figure 15: Set tolerance [PErX] and [PErY]
Press the UP/DOWN buttons to set the tolerance values
Please take your specific tolerance values and X/Y coordinates from the example illustration sheet.
For the X/Y position to be within the tolerance range, the following conditions have to be fulfilled: [rEFX]-[PErX]<[X]<[rEFX]+[PErX]
AND
[rEFY]-[PErY]<[Y]<[rEFY]+[PErY]
4.
-White rectangle=Checker size Reference coordinates [rEFX], [rEFY]
T=Set tolerance [PErX], [PErY]
-TyT
+Tyl
Figure 16: Tolerance setting for edge detection, "OK Rectangle"
Reference coordinates [rEFX], [rEFY] Current coordinates (NG)
Should you have any problems with your LightPix, we would like to assist you as fast and effectively as possible. Therefore, if you have questions that cannot be clarified with the help of manual (order number: ARCT1F384V10EN) and the Easy User Guide, please contact this address: info@lightpix.net
You can help us by having the following data at hand:
• Your product's part number (e.g. ANE1010).
• What happened and what you did when the problem occurred?
• How did you attempt to solve the problem?
In case you find any errors in this documentation or cannot find important information, please do not hesitate to contact our Department of Technical Documentation at tech-doc@euro.de.mew.com.
In no event will Matsushita Electric Works (Europe) AG be liable for direct, special, incidental, or consequential damage resulting from any defect in the product or its documentation, even if advised of the possibility of such damages.
Matsushita Electric Works (Europe) AG Rudolf-Diesel-Ring 2, 83607 Holzkirchen, Germany Tel.: +49(0)8024-648-0, Fax: +49(0)8024-648-111 Internet: www.mew-europe.com www.lightpix.net
Order number: LightPixEasyLeafletEdgeV11.1EN
Figure 17: Tolerance setting for edge detection, "NG Rectangle" For details, see also Figure 6.
Press the SET button shortly to return to the inspection mode
5.
D. Execute an INSPECTION
After having completed the tolerance range settings, an inspection is carried out automatically because the internal trigger [I.trr] is set to ON by default in the environmental configuration mode. In case the LightPix does not trigger automatically, you can trigger an inspection by pressing the TRIGGER button.
1. Check the status of OUT1
Place the "OK Rectangle" and the "NG Rectangle" under the main unit.
If OUT1 is set, the inspection result is "OK".
If OUT1 is not set, the measurements are not within the set tolerance ranges and the inspection result is "NG".
Edge Detection 3