Individual Data Sheets Individual Data Sheets

Panasonic Panasonic HHR330APH/FT HHR330APH/FT

Cylindrical LFat/A size for back up use Cylindrical LFat/A size for back up use (mm)

18.2

+

-

00.7 (+)

2.0
Charge: 330mA(0.1lt) X 16 hrs. 1.41.61.8
Voltage (V) 1.2 1.0
10°C 25°C 60°C

67.0

+

-

01.5

0.8 0 2 4 6 8 10 12 14 16 18 20

Charge time (min)

5.5m

Typical discharge characteristics

(-)

Specifications Typical charge characteristicsDimensions (with tube)

120 110

ChargeStandardRapidLow rateChargeStorage<1 year<6 months <1 month <1 weekDischarge

100

Diameter18.2+0 / -0.7mmHeight67.0+0 / -1.5mmApproximate Weight60g

90 Charge:330mA(0.1 lt) X 16hrs. Charge temperature : -10 to 60°C 5080 Discharge: 660mA
Capacity raito (%) Cut off voltage: 1.0V

Nominal Voltage 1.2V3,300mAh 3,200mAh

Discharge temperature: 25°C 30406070 *1

Average

*2 2 -10 0 10 20 30 40 50 60 70

Discharge Capacity

Temperature °C

Rated (min.) Approx. Internal impedance at 330mA X 16hrs.1,650mA X 2.4hrs.-10°C to 45°C-10°C to 60°C -20°C to 35°C -20°C to 45°C -20°C to 55°C -20°C to 65°C 1000Hz at charged state.

*3

165mA X 32hrs.110mA X 48hrs.

1.81.61.41.21.00.8
Charge: 330mA(0.1 It) X 16hrs. 25°CDischarge: 10A, 20A, 25°C

StandardRapidLow rate -10°C to 60°C

10 A20 A
Voltage (V) Ambient Temperature 0 5 10 15 20 25 30
Ambient Temperature
Discharge time (hours)
*1 After charging at 0.1It for 16 hours, discharging at 0.2It.*2 For reference only. *3 Please consult Panasonic for details of dT/dt.Battery performance and cycle life are strongly affected by how they are used. In order tomaximize battery safety, please consult Panasonic when determining charge/discharge specs, warning label contents and unit design. *The data in this document are for descriptive purposes only and are notintended to make or imply any guarantee or warranty.

7 Nickel metal hydride batteries

DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
pdf-page pdf di En 2008-12-49-02