MCRT 160 Micro Carbon Residue Analysis120SPECIFICATIONS D 4530 TESTING, MICROPROCESSOR PRECISIONOrdering Information MCRT-160 Micro Carbon Residue Tester for safe, precise indication of petroleum materials’ relative coking tendency. Microprocessor-controlled instrument supplied with 2 ml and 15 ml vials (for 180 tests), glass condensate trap with gasket, sample baskets for 2 ml and 15 ml vials, oven seal lid, exhaust chimney, and user manual. – P/N 85435-111:Proven, patented Alcor technology as specified in ASTM D 4530 Precisely, automatically controls each test step — from initial sample warm-up through final cooldown One button test initiation Overnight test modeVAC , 50/60 Hz – P/N 85435-221: 230VAC , 50/60 Hz (European power cord) – P/N 85435-231: Displays test status onLEDreadout for easy viewing230VAC , 50/60 Hz (UK power cord) Continually monitors temperature and nitrogen pressure, alerting technician when parameters exceed operation and/Standard Test Method ASTM D 4530, equivalent to Conradson Carbon (ASTM D 189), D 189; IP 398; ISO 10370, 6615; DIN 51551; GB/T 17144; JIS K 2270or safety limitsULTIMATE TESTING VERSATILITYPatents 4,568,426 and 4,680,167Processes up to 12 samples simultaneously, enhancing laboratory’s test productivityOperation Oven Capacity 600 ml (approximate) Temperature Range Ambient to 775ºC Time Control Multiple programmable steps (seconds, minutes, hours for each step) Overnight Test Mode Continues nitrogen flow for up to 16 hours after cool-downAllows standard sample to be run with every test for verification of test accuracy Accommodates sample sizes from 0.1 to 2 grams (depending on carbon residue content)SafetyPermits routine analysis for carbon residue from 0.1% to over 30%Temperature High temperature limit-switch with auto shut down and audible alarm; test won’t start in over-temperature state Nitrogen Flow Automatic flow control with internal pressure regulator to maintain constant pressure; pressure gauge in kPa and PSIG scales; pre-test low/high flow check and adjustments; low pressure switch with auto shut down and audible alarmENVIRONMENTALLY FRIENDLY OPERATIONSealed oven and directed exhausts results in much cleaner analysis compared to Conradson CarbonRequirementsNitrogen purge gas continuously blankets oven and removes harmful vapor, which are either condensed into an external trap or vented to exhaustNitrogen 135 to 1000 kPa (20–145 psig); cylinder preferred, approx. 37L (1.3 ft3 ) per 95 minute test Electrical Voltage selector switch, easily convert: 120 VAC & 230 VAC IEC-320 connector for detachable power cord Other Close proximity to hood for vapor exhaust; access to analytical balance (0.1 mg accuracy) Physical Dimensions (WxDxH) 26 x 38 x 56 cm (10¼ x 15 x 22 inches) Weight 13 kg (28½ pounds) Optional Accessories Carbon Residue Reference Samples P/N 73122: Low Carbon #1, 0.3% Carbon* P/N 73130: Low Carbon #2, 2.4% Carbon* P/N 73123: Medium Carbon, 10.6% Carbon* P/N 73124: High Carbon, 24.1% Carbon* * Exact %Carbon content may change without notice Vials P/N 17622: Small (2 ml), box of 144 P/N 17623: Large (15 ml), box of 144 P/N 17659: Tall (4 ml), box of 144 Germany Badstrasse 3-5, P.O. Box 1241 D-97912 Lauda-Königshofen FOR ADDITIONAL INFORMATIONYOUR LOCAL REPRESENTATIVE: USA France 8824 Fallbrook Drive, Houston, Texas 77064 Phone: 800.444.TEST [281.580.0339] | Fax: 281.580.0719 sales@paclp.com | service-lab@paclp.com BP 70285 - VERSON - 14653 CARPIQUET Cedex +33 (0) 231 264 300 | fax +33 (0) 231 266 293 sales@paclp.fr | service@paclp.fr +49 9343.6400 | fax +49 9343.640.101 sales@paclp.de | service@paclp.de Singapore 10, Eunos Road 8, #12-06 Singapore Post Centre 408600 +65 6742 8453 | fax +65 6742 8759 sales@paclp.com.sg | service@paclp.com.sg© Copyright 2003 PAC L.P. |H-03-MCRT160-4M|Printed in USA www.paclp.com |
|