You may also be interested in
Analyzer, Colorimeter, Total hydrocarbon analyzer, Viscometer, Detector
Text version of the page
HERZOG HFPHFP 339 - AUTOMATIC CLOSED CUP PENSKY-MARTENS FLASH POINT ANALYZER - 9054 339FLASH POINT ANALYZERSPECIFICATIONSOrdering Information HFP 339 Pensky Martens Flash Point Analyzer is a compact and self-contained instrument for precise Flash Point determination. Included is a user friendly manual machine interface, electric (standard) or gas (optional) ignition and thermal detection. Standard Test Methods ASTM D 93 A&B, ISO 2719 A&B, EN ISO 2719 A&B, DIN EN ISO 2719 A&B, NF EN ISO 2719 A&B, DIN 51758, IP 34 A&B, JIS K 2265 Measuring Programs Flash point determinations may be run using standard test method or customized test protocols; 6 standard programs and 3 user defined programs. Operation Temperature Range Per appropriate method or user defined; 0 to 400°C Heat Rate Per appropriate method or user defined 0.5 to 14K/min; Proven automatic algorithm with heater block temperature and sample temperature controlElectric (standard) or gas (optional) ignition; adjustable test interval 0,5 to 5K; Thermal; eliminates interference from water or silicone-containing samples IgnitionDetection Sample Stirring Per appropriate method or user defined 20 to 255 rpm Barometric Pressure Correction Built in barometric pressure sensor 700 to 1100 hPa; Flash Point is automatically corrected to barometric pressure; Cooling Built in fan with preprogrammed temperature for heater block cooling upon test completion, Pre cooling for heater block with optional cooling cup Safety Fire Extinguisher Over Heating Protection A built-in fire sensor instantly alerts user to flames outside the flash cup. A potential-free alarm relay contact is also available to link the HFP to fire suppression or remote alarm system. Automatic heater shut down and audible signal when abnormal heater or sample temperature The unit automatically recognizes a wrong sample for a given specification Safety Pre-test Password Security Password protection for parameter and calibration Calibration & Diagnostics Automatic calibration for temperature measuring unit Function for probe calibration and pressure sensor calibration in the menu Automatic diagnostic routines on all analyzer functions and messages for erroneous functions Documentation On-screen real-time display of temperature and ambient pressure; last 9 results memory; detailed test report, date & time stamped Output to printer; transmitted to a PC and/or LIMS via built-in RS323 serial link Multiple units can employ single printer or LIMS gateway by HTR network Parameter print out Operating Requirements Ambient Electrical Temperature 10 to 35ºC; relative humidity 80% at 35°C 115V or 230V switchable; 50-60Hz; 1100 W Dimensions & Weight 25cm W x 56cm D x 51cm H; 25 kg 9.85’’ W x 22’’ D x 20.1’’ H; 55 lbACCESSORIESCooling Cup For sub-ambient testing (below 40°C) cooling cup for pre cooling of heater block Low Volume CupMetal Sample ProbeCertified Reference Material 20 mL cup for low volume applications FP approx. 65°C and FP approx. 215°C Parallel DeskJet printer or Dot Matrix ticket printer PrinterDue to continuing product development, specifications subject to change at any time without notice. All Herzog products are compliant. Herzog Token Ring Netware allows easy resource sharing and facilitates LIMS connection. Single printer and LIMS gateway can be used by up to 16 HFP units in your lab.FOR ADDITIONAL INFORMATIONYOUR LOCAL REPRESENTATIVE: USA Germany 8824 Fallbrook Drive, Houston, Texas, 77064 Badstrasse 3-5, P.O. Box 1241 D-97912 Lauda-Königshofen Phone: 800.444.TEST [281.580.0339] | Fax: 281.580.0719 +49 9343.6400 | fax +49 9343.640.101 sales@paclp.com | service-lab@paclp.com sales@paclp.com.de | mail@service.paclp.de France Singapore 10, Eunos Road 8, #12-06 Singapore Post Centre 408600 BP 70285 - VERSON - 14653 CARPIQUET Cedex +33 (0) 231 264 300 | fax +33 (0) 231 266 293 +65 6742 8453 | fax +65 6742 8759 sales@paclp.com.fr | service@paclp.fr sales@paclp.com.sg | service@paclp.com.sg © Copyright 2006 PAC L.P.|HFP339 ver 1.0|Printed in USA 0506 www.paclp.com |
|