SGD-GEM - ORTEC - #1

/ 12


catalogue search
SGD-GEM - ORTEC
P. 01
SGD-GEM - ORTEC
P. 02
SGD-GEM - ORTEC
P. 03
SGD-GEM - ORTEC
P. 04
SGD-GEM - ORTEC
P. 05
SGD-GEM - ORTEC
P. 06
SGD-GEM - ORTEC
P. 07
SGD-GEM - ORTEC
P. 08
SGD-GEM - ORTEC
P. 09
SGD-GEM - ORTEC
P. 10
SGD-GEM - ORTEC
P. 11
SGD-GEM - ORTEC
P. 12
Pages:
SGD-GEM - ORTEC


See other catalogues for ORTEC

Text version of the page
• Specifically designed to meet the demanding requirements of isotopic ratio software codes used in Safeguards and NDA. • Excellent resolution is maintained over a wide range of count rates, enhancing measurement flexibility. • Available in a full range of crystal diameters. • Extensive range of cryostats with multi-orientation dewar options for applications requiring portability. • Compatible with all existing Safeguards multichannel analyzers. The precise measurement of isotopic ratios required in Safeguards and non-destructive assay (NDA) applications places a severe demand on the techniques of gamma-ray and x-ray spectroscopy. Figure 1 demonstrates the complexity of the 90–130 keV region of a typical Pu spectrum. (The choice of energy region(s) for analysis depends specifically on the sample type and origin and the material matrix. National laboratory software codes1 written to obtain highly accurate isotopic ratios, must deal with these spectra to analyze low-energy and/or high-energy regions in which groups of peaks are located close together. Each code requires exceptional system resolution and stability in order to achieve accurate unfolding of these regions. Recent safeguards development trends have led to a growing requirement of isotopic ratio determinations involving higher energy gamma-rays. Such needs spring from the need to measure attenuated samples, such as those found in waste assay and in certain homeland security applications. Software codes such as PC/FRAM and MGAHI2 can now determine Pu isotopic ratios from the higher energy regions of the spectrum. As a consequence, it is desirable to produce HPGe detectors that offer improved higher energy performance, while maintaining the excellent resolution characteristics required in such applications. The ORTEC Safeguards series include both coaxial and planar geometry detectors, specifically designed to meet the demands of the applications software used for isotopic ratio determination, have been developed to strike an optimum balance between low-energy resolution and high-energy efficiency. SGD series detectors are compatible with ALL conventional MCA types, although optimum performance will be obtained when used with the ORTEC Digital Signal Processing Spectrometers. All SGD detectors feature the following: • Choice of fixed, portable, and custom cryostats, including the latest MOD multi-orientation dewar option. • Robust aluminum end-cap • Streamline preamplifier assembly • LN2-Free option The latest low-power resistive feedback preamplifier with "no ring" output, suitable for use with all existing types of MCA systems. Power consumption less than 25 mA at ±12 and ±24 V. High-Performance Germanium Coaxial Detectors for Safeguards and Non-Destructive Assay Product Configuration Guide ORTEC® Fig. 1. The 90 to 130 keV region of a typical plutonium spectrum.

pageCatalog pdf di En 2012-05-22-31