StandardACMotors
Induction Motors - 15580 General SpecificationsΩ or more when 500 VDC is applied between the windings and the frame after rated motor operation under normal ambienttemperature and humidity.Sufficient to withstand 1.5 kV at 50 Hz and 60 Hz applied between the windings and the frame for 1 minute after rated motor operation undernormal ambient temperature and humidity.Temperature rise of windings are 144ËšF (80ËšC) or less measured by the resistance change method after rated motor operation withconnecting a gearhead or equivalent heat radiation plateWorld K Series, V Series, K Series (Conduit Box Type)Introduction ✽ . [Three-Phase 6 W type : 126ËšF (70ËšC)]Class B (266ËšF [130ËšC])6 W type have impedance protection. All others have built-in thermal protector (Automatic return type) Operating temperature, open : 266ËšFInductionMotors InductionMotors 9ËšF (130ËšC 5ËšC) close: 179.6ËšF 27ËšF (82ËšC 15ËšC)14ËšF 104ËšF ( 10ËšC 40ËšC) [Three-phase 200 VAC: 14ËšF 122ËšF ( 10ËšC 50ËšC)] (nonfreezing)85% maximum (noncondensing)Type (output) ReversibleMotors K Series, V Series): IP 20Terminal box type (World K Series, V Series): 25 W, 40 W IP 5460 W, 90 W IP 44 SynchronousMotors ✽ Heat radiation plate (material: Aluminum)TorqueMotors 2IK TypeSize: in. (mm) 4.53 (115 115)4.92 3IK Type 4.92 (125 125)5.31 4IK Type 5.31 (135 135)6.50Watertight Motors 5IK40 Type 6.50 (165 165)7.87 5IK60 Type 7.87 (200 200)7.87 5IK90 Type(6 W)(15 W)(25 W)(40 W)(60 W)(90 W)4.53 7.87 (200 200)Thickness: in. (mm)0.20 (5) MagneticBrake Ω or more when 500 VDC is applied between the windings and the frame after rated motor operation under normal ambienttemperature and humidity.Sufficient to withstand 1.5 kV at 60 Hz applied between the windings and the frame for 1 minute after rated motor operation under normalambient temperature and humidity.Temperature rise of windings are 135ËšF (75ËšC) or less measured by the resistance change method after rated motor operation.Class A (221ËšF [105ËšC])( K SeriesClutch &Brake ItemInsulation ResistanceDielectric StrengthTemperature Rise Insulation ClassOverheat ProtectionAmbient Temperature RangeAmbient Humidity Specifications100 MBrakePack 0IK1GN-AUL , 0IK1A-AUL , 5IK90A-BFUL : UL/CSA Standards···Class A, EN Standards···Class E)14ËšF Right-Angle Gearheads 9ËšF (120ËšC 5ËšC) close: 170.6ËšF 27ËšF (77ËšC 15ËšC)85% maximum (noncondensing) 104ËšF ( 10ËšC 40ËšC) (nonfreezing)1 W type is impedance protected. All others have built-in thermal protector (Automatic return type) Operating temperature, open: 248ËšF Accessories Degree of ProtectionIP20 Before Usinga StandardAC Motor BH SeriesItemInsulation ResistanceTemperature RiseInsulation ClassOverheat ProtectionAmbient Temperature RangeAmbient Humidity Dielectric StrengthSpecifications100 M Ω or more when 500 VDC is applied between the windings and the frame after rated motor operation under normal ambienttemperature and humidity. Sufficient to withstand 1.5 kV at 50 Hz and 60 Hz applied between the windings and the frame for 1 minute after rated motor operation undernormal ambient temperature and humidity.Temperature rise of windings are 144ËšF (80ËšC) or less measured by the resistance change method after rated motor operation withconnecting a gearhead or equivalent heat radiation plate✽ . [Three-Phase type: 126ËšF (70ËšC)]Class B (266ËšF [130ËšC])Built-in thermal protector (Automatic return type) Operating temperature, open : 302ËšF 9ËšF (150ËšC 5ËšC) close : 204.8ËšF 27ËšF (96ËšC 15ËšC)14ËšF 104ËšF ( 10ËšC 40ËšC) [Three-Phase 200 VAC: 14ËšF 122ËšF ( 10ËšC 50ËšC)] (nonfreezing)85% maximum (noncondensing)Degree of ProtectionCable Type: IP40Terminal Box Type: IP54 Degree of ProtectionLead wire type (World ✽ Heat radiation plate: 9.06 inch 9.06 inch (230 mm 230 mm), 0.20 inch (5 mm) thickness (Material: Aluminum) ItemInsulation ResistanceDielectric Strength Temperature RiseInsulation ClassOverheat ProtectionAmbient Temperature RangeAmbient Humidity Specifications100 M A-17 |