Catalogue excerpts

A-212 0.36°/Geared Stepper Motor and Driver Package •Technical reference ➜ Page H-1 •Regulations & Standards ➜ Page I-2 AR Series ●For detailed information about regulations and standards, please see the Oriental Motor website. A closed loop stepper motor series that substantially reduces heat generation from the motor through the use of high-efficiency technology. The driver is a highly functional, compact DC power supply input type. Built-in Controller Type •High Reliability with Closed Loop Control • High Efficiency Technology Reduces Motor Heat Generation •Capable of High Positioning Accuracy •2 Driver Types to Choose from Built-in Controller Type /Pulse Input Type Pulse Input Type What is FLEX? FLEX is the collective name for products that support I/O control, Modbus (RTU) control, and FA network control via network converters. These products enable simple connection and simple control, shortening the total lead time for system construction. ■Features High Reliability with Closed Loop Control A Single Driver to Support a Variety of Motors For details, refer to Page A-9 "Overview of Closed Loop Stepper Motor and Driver Packages ". Continuous Operation Utilizing High-Efficiency Technology ●Lower Heat Generation The driver is equipped with an automatic recognition function, which recognizes the attached motor. Various types of motors, such as the standard type and the geared type, can be attached to a single driver. Therefore, there is no need to change the driver to match the motor to be attached. Maintenance is easier. TH Geared Heat generation by the motor has been significantly reduced through higher efficiency. ● Temperature Distribution by ● Motor Case Temperature under Thermography Same Operating Conditions Conventional Product Comparison under the Same Conditions. ●35% Less Power Consumption✽ than Conventional Oriental Motor Products Due to Energy-Saving Features Harmonic Geared Products Equipped with the AR Series All of the products equipped with the AR series feature standardized controllability. ● Power Consumption Power Consumption [kWh/Year] Power Consumption 35% Reduction ✽Operating Condition · Speed: 400 r/min, load factor 50% · Operating Time: 24 hours of operation, 365 days/year (70% operating, 25% stand-by, 5% off) Conventional Product Stepper Motor and Driver Package Hollow Rotary Actuators Same Movement! ●Continuous Operation (Operation at a High Duty Cycle) The AR Series can be operated at high frequency. The motor can operate continuously. Electric Linear Slides Electric Cylinders You don't need to worry about the duty cycle. Note ●If the motor is operated continuously, a heat sink of a capacity at least equivalent to an aluminum plate with a size of 100×100 mm, 6 mm thick is required. ORIENTAL MOTOR GENERAL CATALOGUE 2017/2018 Features A-212 / System Configuration A-219 / Product Line A-221 / Specifications, Characteristics A-225 Dimensions A-243 / Connection and Opera

 Open the catalogue to page 1

Stepper Motors Highly Functional, Compact Driver ●Compact DC Power Supply Input Driver This a compact driver. This contributes to space saving for the control box and equipment. The driver can be installed directly to a DIN rail, so no screws are necessary. The motor runs on a 24 VDC or 48 VDC power supply. Choose the power supply that you have available. The torque is higher when 48 VDC is used rather than 24 VDC. (Frame size 20 mm and 28 mm only accepts 24 VDC input.) AR66AK-◇ Overview, Product Series 1.5 AC Input Motor & Driver ●Built-in Controller Type ●Pulse Input Type ●Push-Motion Operation...

 Open the catalogue to page 2

0.36°/Geared Stepper Motor and Driver Package AR Series 2 Driver Types Available Depending on the System Configuration 2 types of AR Series drivers are available, depending on the master control system in use. ●Built-in Controller Type ● When Controlling with I/O Power Supply No Need for CPU Positioning I/O Module ●Pulse Input Type ● When Controlling from Computer or Touch Screen (HMI) ● When Controlling with Serial Communication Power Supply CPU Serial Communication Module ● When Controlling with FA Network Power Supply Power Supply Positioning Module Pulse Input ③FA Network ①I/O Network Converter ②RS-485...

 Open the catalogue to page 3

Built-in Controller Type CFLED' Because the driver has the information necessary for motor operation on built-in controller types, the burden on the host PLC is reduced. The system configuration when using multi-axis control has been simplified. Settings are configured using a control module (sold separately), data setting software or RS-485 communication. Basic Setting (Factory setting) Operation Data Setting Parameter Changing Data Setting Test Operation Overview, Product Series AC Input Motor & Driver Alarm History Parameter Changing Data Setting Software (MEXE02) Data Copy • Setting using...

 Open the catalogue to page 4

0.36°/Geared Stepper Motor and Driver Package OCstep AR Series Positioning Operation <Operation Functions> • Independent Operation Speed Start Command . • Linked Operation Speed Start Command Dwell Time • Linked Operation 2 Speed • Group Send Function Modbus (RTU) communication and FA network have a function that enables multiple shafts to be started simultaneously. Multiple drivers can be grouped together, and when an operation command is sent to the master driver, all the drivers that belong to the same group as the master driver will operate simultaneously. Start Command • Push-Motion Operation...

 Open the catalogue to page 5

Pulse Input Type The control module (sold separately) and data setting software can be used to change the parameters, display the alarm history, and perform various types of monitoring. Basic Setting Extended Settings or Data Setting Software (MEXE02) Push-Motion Operation Test Operation Alarm History Parameter Changing Data Copy Overview, Product Series AC Input Motor & Driver AR • Main Additional Functions Available with Extended Settings DC Input Motor & Driver Motor Only /Driver Only Geared PKP/PK ❖ 1 Do not perform push-motion operation using geared type motors. Doing so may damage the motor...

 Open the catalogue to page 6

All Oriental Motor catalogues and technical brochures

  1. Brake Pack

    4 Pages

    En
  2. Torque Motors

    8 Pages

    En
  3. TM Series

    32 Pages

    En
  4. PKP Series

    28 Pages

    En
  5. CVK Series

    36 Pages

    En
  6. EAS Series

    128 Pages

    En
  7. DRS2 Series

    20 Pages

    En
  8. EZS Series

    13 Pages

    En
  9. NX Series

    44 Pages

    En
  10. DGII AR

    52 Pages

    En
  11. MBS - Series

    6 Pages

    En
  12. MBD - Series

    7 Pages

    En
  13. MF - Series

    4 Pages

    En
  14. MFD - Series

    4 Pages

    En
  15. AZ DC - Series

    43 Pages

    En
  16. AZ AC - Series

    47 Pages

    En
  17. BLV - Series

    16 Pages

    En
  18. BLH - Series

    16 Pages

    En
  19. BLE2 - Series

    20 Pages

    En
  20. BMU - Series

    20 Pages

    En
  21. FPW - Series

    8 Pages

    En
  22. World K - Series

    50 Pages

    En
  23. World K - Series

    25 Pages

    En
  24. KII - Series

    60 Pages

    En
  25. Product Range

    12 Pages

    En
  26. Cross Flow Fans

    2 Pages

    En