OP930 Insertion Loss & Return Loss Meter Insertion Loss (IL) and Return Loss (RL) on fiber optical components are measured fast and accurately with the OP930. The return loss is measured with the “no mandrel” method, meaning neither matching gel nor mandrel wraps are required at the far end of the cable. The insertion loss is measured by utilizing the stable transmitter of the Return Loss as the source in combination with the precision optical power meter. Like other OptoTest equipment the OP930 supports the USB interface. The OPL-PRO turnkey application software fully integrates this instrument into the data acquisition process of the high efficient production line. Insertion Loss & Return Loss Meter Insertion Loss and Return Loss Measurement • Fully automated, concurrent dual wavelength IL and RL • Both readings, insertion loss and return loss at the same time • Multimode return loss to qualify GbE cables • USB Interface to custom application or included OPL9 application support writing directly to a spreadsheet • HPR Reference cable included Optical Power Measurement • “State of the Art” fiber optic power meter • Various detector options for single fiber, MT-RJ and MTP/MPO multifiber connectors • Automated dual wavelength insertion loss measurement Return Loss Measurement • No mandrel wrap nor matching gel • Singlemode: 10dB to >72dB Return Loss • Multimode: 10dB to 50dB Return Loss 805.987.1700 sales@optotes t.com engineering@optotes t.com OptoTest Corp. 4750 Calle Quetzal Camarillo,CA 93012 NEW Features NEW Overview OP930-SM-13/15 OP930-MM-1300 Detail Specifications Specifications are subject to change, please confirm specific per formance characteristics of the product at the time of ordering. All specifications are valid within temperature range of 18º C to 24º C unless otherwise noted. 1) NIST traceable calibration at -10dBm. 2) Linearity for loss <5dB and absolute power within -3dBm...-45dBm. Optical Power Meter Measurement Range +10dBm ... -80dBm Wavelength Range 830nm ... 1700nm (InGaAs Detector) Selectable Wavelength Standard: 850/1310/1550/1625nm 1) Measurement Resolution (Display) 0.01dBm (absolute), 0.001dB (relative) Measurement Linearity, Relative Accuracy 0.05dB 2) Return Loss Meter Source Wavelength 1310nm, 1550nm or both 850nm or 1300nm Measurement Range 10dBm ... 72dBm 10dBm ... 52dBm Optical Inter face SM: 0.5dB <50dB, 1dB >50dB MM: 0.5dB <45 dB Power Supply 0.1 dB Distance Range 2.5m ... 2400m Model OP930 Inser tion Loss and Return Loss Meter

pageCatalog pdf di En 2012-05-22-31