LDS-2000 - 1

Model LDS-2000 Laser Doppler Scale LASER SCALES FOR POSITIONING APPLICATIONS High accuracy and high resolution. No need for periodic calibration. Non-Contact eliminates parts wear. Freedom locate point of measurement close to measured object reduces Abbe Error. Orthogonality of positioning system determined by mirrors not X-Y stages when using flat mirror target. Electronics flexibility with variable increment and automatic temperature compensation. No mounting stress on scale. No thermal expansion on scale. No need for machined fiat surface for mounting scale saving installation costs. Higher loop gain possible for closed loop servo control. Optional hermetic seals for hostile environments. Rejection of vibration in two or three planes reduces structural resonance effects. Precision Positioning with Environmental Compensation SYSTEM COMPONENTS The LDS-2000 Laser Doppler Scale (LDS) with Automatic Temperature, Pressure and Material Thermal Expansion Compensation provides high speed, high accuracy and long range positioning for single or multiple axis applications, such as linear motors, large gantry machines, CNC machine tools, CMM's, precision stages, Supermi-crometers, and other linear measurement devices. The LDS is compact, easy to install, easy to align, has less Abbe off-set, no cross coupling, and is cost effective. L-109 Laser Head-HeNe Laser head, ruggedized for direct installation in machine tool and other positioning applications. Contains HeNe Tube, Optics and a Photodetector Receiver. Outputs to IPS 1 Processor Module. The LDS is compatible with all mainstream controller feedback systems, and the laser head is insensitive to dirt, oil, and hostile environments. The LDS Laser Head reflects a modulated laser beam off a movable target. The beam is detected and processed for displacement information used by your system controller to determine position. Installation is made easy with only four components; the laser head, the retroreflector, the processor module, that produces either AQuadB Square Waves or Up/Down Pulses and the IACTM Automatic Temperature/ Material Compensation System. The LDS-2000 can directly replace glass scales and other positioning devices in your existing systems. Optional cards include RS232, and Sinusoidal outputs. IPS1 Processor Module - Contains the electronics for signal processing and generation of the AQuadB Square Waves and Up/Down Pulses. Receives signal directly from the Laser Head. The processor mounts in the P-108 AC Powerfeed and Enclosure. The standard output is Up/Down Pulses. For AQuadB instead of Up/Down Pulses, please specify at time of order. The board also provides an error signal that is a TTL level output, which is LOW to indicate that the laser signal is low and HIGH to indicate that the laser signal level is sufficient for normal operation. An Optional Error Signal/ Warning Signal Latching Relay is also available. See IEWR Relay for Warning and Error R-102A Retroreflector - 1/2" diameter retroreflector without post or base. Used to return the laser beam back to the Laser Head receiving aperture on a path parallel to the input beam, regardless of the angle of incidence. Movement of the retroreflector determines displacement measurement. IATCM Automatic Temperature/ Pressure Compensation (Master) -Consists of an Air Pressure Sensor, an Air Temperature Sensor, a Material Temperature Sensor, and a CPU controlled board. The values of Pressure, Temperature and Material Temperature are used to calculate the compensation factor. The Material Thermal Expansion Coefficient is loaded into the CPU through the RS-232 port on your PC. Software is provided to change the

Open the catalog to page 1
LDS-2000 - 2

Material Thermal Expansion Coefficient, which corresponds, to the material to be machined. A second material temperature sensor, Model IMS is also available as an option. Each IATCM can control up to 5 Model IATCS Slave units. LD-21R Cable Set - Connects the Laser Head to the IPS 1 Processor Module. If P-108L Powerfeed Enclosure is used, specify LD-21L Cable Set. P-108 AC Powerfeed and Enclosure – Power source for the Laser Head and the IPS 1 Processor Module, that is mounted in the P108 enclosure. Supplies +15V and ±5V, input connectors and a terminal strip, for connection to your...

Open the catalog to page 2
LDS-2000 - 3

Retroreffector Gun Barrel Attachment - 3" tube that attaches to the front of the retroreflector to provide protection against oil and flying. debris. LD51S 90 degree beam bender - Fixed 90 degree mirror those attaches to front of Laser Head. P-108L AC Powerfeed and Enclosure with Terminal Strip, Lemo Connectors - Same as P-108, but uses Lemo Connectors for the power system instead of SMA/SMB type. The Lemo Connectors provide a higher strain relief, and are ideal for more rugged applications. Specify LD-21L Cable if this option is used. LHS1 Hermetically Sealed - Sealed Laser Head with the...

Open the catalog to page 3
LDS-2000 - 4

SPECIFICATIONS: HIS Home Position Signal Output: TTL Square Wave Termination: 120 Ohms Rise Time: 15 nsec Pulse Width: 5 msec Repeatability: < lµm L-109 Laser Head: Power: 0.5 mw HeNe C1ass:II 1121 CFR 1040.10, 1040.11 Alignment Tolerance: lateral ±0.05 inches Wavelength: 632.8 nut Weight: 2 lb. Warm-up Time: 20 minutes Operating Environment: Temperature 60 to 90° F Altitude 0 to 10,000 ft Humidity 0 to 95% non-condensing Resolution/Slew Rate: IPS1 Processor Card: 25 microinches (0.6 µm), slew 160 ips 1PD2 Divide by 8 Board: Dimensions System Components: IPS1 Processor Card: 7 x 4.5 x 0.75...