| | | (T) Sensor input waveform From top to bottom, sensor input 0,1, 2, and 3. The right side is the new pattern. Green: OK-judged pattern position Red: NG-judged pattern position (2) Time axis of waveform Clearance between red points is the time displayed on (15) and (16). (§) Registered pattern waveform Displays the waveform teaching has been performed. @ Input waveform display starting pattern count In displaying the input waveform, starts from the last patterns by specified counts. (0 - 255) (D Registered waveform display starting pattern count In displaying the registered waveform, starts from the last patterns by specified counts. (0-251) (6) Sorted result Displays the sorted bank number. (0 - 6: Bank number, -: Without) ® OK counter setting value Displays the COUNTER setting value. Displays AOO when the setting value is 1000. (8) Concordance rate Concordance rate when comparing the patterns. (0-100) (§) Bank number Displays the current bank number. (0 - 6) © Actual OK counter value Displays the actual OK counter value. (0 -999) | | © Concordance rate bar graph Gray: Without object (less than NG LVL) Red: NG (less than OK LVL) Green: OK (OK LVL or more) © Analog input selection status Displays the analog input voltage/current selection switch status. V: Voltage input I: Current input (3) Analog input value Displays the value after offset/span conversion as 0 - 9999. Displays FFFF when inputting overvoltage. <3> Sensor input ON/OFF status 0 - 3: Turned ON. (Number in accordance with INO - IN3) -: Turned OFF. X: Masked. (Refer to the setting value MASKING) © Registered pattern waveform display time Time axis that the registered pattern waveform displays (the time between the red marks). <8) Sensor Input waveform display time Time axis that the sensor input waveform displays (the time between the red marks). © Setting value Displays the setting value of menu. (£§> Processing time Time to detect the concordance rate with the registered pattern. <@> Menu Yellow: Common to the all banks Purple: The setting value switches according to each bank. Blue: Locked | | |
| | | When objects continuously flow: When objects flow continuously, teaching cannot complete by the time-out due to continuous input changing. In this case, teaching can complete with either of the following conditions: (1) The time approx. 4 times as long as the time-out setting value has passed. (2) The sampled pattern counts 255 or more. | | |