New LED controller power supply OPPF series and sensing LED Bar lighting OPB-S series - 4 Pages

- High performance as well as OPB series
LED controller Advanced
OPPF series
Sensing LED bar lighting
OPB-S series
LED lighting controller Advanced OPPF series
Sensing LED bar lighting OPB-S series Specifications of OPB-S series
- Adjustable multiple lightings same
brightness easily
- “FALUX sensing” technology built-in
- PWM brightness control & strobe drive
- “FALUX sensing” technology for monitoring and feedback controlling
- Brightness is controllable through RS232/Parallel/Analog 0-5V
Communication between the controller and
the LED lighting enables accurate monitoring
and feedback brightness controlling.
74623-01-300410-1102
White
7,000K
DC12V
Housing : Aluminum , PBT Lens : PC
CE, RoHS
50 × 15
100 × 15
150 × 15
200 × 15
250 × 15
300 × 15
60
85
110
145
175
205
3.1
6.2
9.4
12.5
15.6
18.7
OPB-S5015W
Part number Light color
Conformity
Material
LED life
Color Temp.
Size [mm] Weight [g] Power dissipation [W]
OPB-S10015W
OPB-S15015W
OPB-S20015W
OPB-S25015W
OPB-S30015W
Sensing LED bar lighting
OPB-S series
LED controller Advanced
OPPF series
OPPF-30MN
NPN
OPPF-30MP
PNP NPN PNP
OPPF-30SN OPPF-30SP
DC24V±10%
PWM mode : 30W max. (2ch total), Strobe mode : 15W max. (each channel)
PWM mode : 2.5A max. (2ch total), Strobe mode : 4.5A max. (each channel)
Frequency : 20/50/100kHz (for strobe mode as well), Adjustable Duty maximum step : 1000
PWM mode : DC12V (DC11~18V for feedback control), Strobe mode : DC18V (DC16~22V for feedback control)
Feedback OFF : 1.8A max. / Feedback ON : 2.5A max.
2ch
Synchronous input : 2, Analog/Digital switch : 1
Voltage between common and input : 5V min. for ON / 1.2V max. for OFF (30V max.)
Synchronous input : 2, Analog/Digital switch : 1
LED brightness (alarming is available with threshold) / LED temperature, Monitoring frequency : brightness: 21ms, Temp.: 105ms
Pulse width : 10ìs~9.99ms (10ìs step, adjustable maximum step: 1000), Duty : 10% max. (output voltage is 12V when pulse > 1ms)
±1.5% max.
Over current
Over current
Synchronous input response time : 24V input : OFF->ON : 5ìs / ON->OFF : 60ìs, 5V input : OFF->ON : 44ìs / ON->OFF : 41ìs
Input impedance between common and input : 6.8kÙ, insulated by photo coupler, Other input response time: 5~13ms
Voltage : 0~5V, Input impedance : 220kÙ (not isolated)
LED output over current alarm : 1, Feedback alarm : 2, LED output busy : 2
Error: 1 (Logic: “LED output over current” or “LED over heat” or “Feedback error”)
Open collector, 100mA Max./DC30V, Residual voltage : 1.0V max.
Open collector, 100mA Max./DC30V, Residual voltage : 1.5V max.
Over heat of internal circuitry (drop PWM duty to 25% when over 105Ž)
LED over heat, LED brightness alarm when lower than threshold
RS232 1ch, Baud rate : 4800/9600/19200/38400/57600/115200
IR communication : RS232 link to slave unit, Parallel I/F link to slave unit including brightness control and Bank switching,
Transferring error status from slave unit to master unit, copying setup
Communication cycle : approx. 25ms
0~45Ž / 35~85%/RH (without condensation)
0~40Ž / 35~85%/RH (without condensation)
-20~70Ž / 35~95%/RH (without condensation)
-20~70Ž / 35~95%/RH (without condensation)
10~55Hz 1.5mm X, Y, Z 2hours
10G X, Y, Z 3 times
10~55Hz 1.5mm X, Y, Z 2hours
10G X, Y, Z 3 times
10MÙ min./DC500V
Housing : PC
IP20
CE, RoHS
Instruction manual in CD-ROM
385g 375g
Par t number
Type
Power supply
LED output
Power dissipat ion
OPB-S5015W
OPB-S10015W
OPB-S15015W
OPB-S20015W
OPB-S25015W
OPB-S30015W
: 50 × 15mm
: 100 × 15mm
: 150 × 15mm
: 200 × 15mm
: 250 × 15mm
: 300 × 15mm
OPPF-30MN : master unit NPN
OPPF-30MP : master unit PNP
OPPF-30SN : slave unit NPN
OPPF-30SP : slave unit PNP
Patent pending
Line up
Output power
Output vol tage
Output cur rent
PWM cont rol
Moni tor ing
Input
Analog input
Insulat ion impedance
FB cont rol accuracy
St robe cont rol
Parallel input for brightness control: 10 (4 are used for switching Bank)
Write signal for parallel input : 1, Channel switch : 3
Output
LED output protect ion
Output protect ion
Other protect ion
Communicat ion I /F
Operat ing Temp. /Humid.
Storage Temp. /Humid.
Operat ing Temp. /Humid.
Storage Temp. /Humid.
Vibrat ion resistance
Shock resistance
Vibrat ion resistance
Shock resistance
Communicat ion
between Master
and slave
Mater ial
Weight
Protect ion category
Conformi ty
Accessor ies
* Dimensions are on the page 3
* Dimensions are on the page 6
Power supply
10k hours when brightness drops 10% / 100% duty, 30 deg.C (typical)
Heat transition sheet: Silicon rubber
Accessories Diffuse plate (60%, 80%), Transparent cover, Polarizing plate, Bracket

New LED controller power supply OPPF series and sensing LED Bar lighting OPB-S series
  1. P. 1

  2. P. 2

    - Filter time factor for Sync input (for noise reduction)Claw for mountingon DIN rail(back side)DIP switchMIL14 pinconnectorEXT SYNCLED outputconnector...
  3. P. 3

    ö4.520110111114388.5 (for DIN rail)4.5(17.6) 1048778 4 326.27.2143+0.2408-ö4.5 or M4+0.50 40+0.50 40+0.5040 401581585~24VPower supplyPLC(NPN)PLC(NPN)PLC(NPN)Machine...
  4. P. 4

    OPB-S30015W100 10030018.624 15100 1002.5 2.5 2.5 2.52.5 2.525018.624 15OPB-S25015W10020018.624 15OPB-S20015W15515010018.621.3 15OPB-S15015W6010510018.621.3...
Text version