Digital amplifier with modular laser optics
Dual Digital Display
Specifications
MODEL
2CH output type
1CH output type
Master unit 6 wires
Slave unit 4 wires
Master unit 3 wires
Slave unit 1 wire
Cable type
DSA-M(N/P)
DSA-S(N/P)
DSA-M(N/P)3
DSA-S(N/P)1
M8 connector type
-
-
DSA-M(N/P)-M8
Adaptable sensor head
DS Series sensor head only
Response time
Mtyre / 500//S / 2ms (Fast/Standard/Long)
Control output
NPN / PNP Open collector Load current: 100 mA or less Residual voltage:1.8 V or less
Indicator light
Laser emission indicator light: Green, Output Indicator light: Orange Teaching indicator light: Red Channel indicator light: Green
Digital display
7 segment 8 digit display
Timer function
OFF, On delay, Off delay, One-shot
Timer period
1 ms - 9 s
Mutual interference prevention
4 pes Max
Output mode
Light on / Dark on selectable
Analog output
Current output:4 - 20 mA
-
External setting
External input setting (1 point teaching, synchronizing input, laser off, counter reset) Output setting (2CH output analog output)
External input setting (1 point teaching, synchronizing input, laser off, counter reset) 'Settable only with DSA-M -M8
Operating temperature/humidity *1
-25 to +55°C / 35 to 85 % RH (No freezing)
Store temperature/humidity
-40 to +70°C / 35 to 85 % RH (No condensation)
Power source, voltage
12 - 24 V DC ± 10 % including a ripple
Consumption current
45 mA or less / 24 V
Shock resistance
10 to 55 Hz Double amplitude 1.5 mm 2 hours for each direction of X, Y, and Z
Protective category
IP50
Material
PC: Case and cover
Weight (including the codes)
Cable type: 65 g M8 connector type: 30 g
Channel indicator Teach Mode Indicator
UP DOWN Teaching button button button
1CH output indicator -Laser emission indicator -2CH output indicator
:ou" —I Ml Zi ~J zt moo
M J Jl <J J J _<
L
J L
SET/RUN selector Mode button Channel Indicator
i i
Received light Threshold
6 ways teach-in method for your convenience Difference Sensing Mode
Bumpy conveyor always prevents sensors from stable detection. DS series solves this typical problem by its Difference Sensing Mode. The Master and the Slave keep on computing the gap of reflection between background and surface of object, (see the picture below)
No matter how the background like conveyor surface fluctuates , DS is not influenced with it, and possible to trace the object.
One Point Teaching
Diffuse Reflective Retro/Thru-beam
Use this teaching mode when no object is there.
Find the threshold so the sensor would not detect the background.
Operation Flow:
Two Point Teaching
Remark(1) 4CCat 12V DC in case of inter-connection up to 30 pes or Parallel installation up to 50 pes. Remark(2) BIF series amplifier is not possible to connect with other amplifiers due to different response time.
Display
Computing
Display
Reflection gap between Master and Slave
This is the basic way of setting for Diffuse Reflective DSD-100. One teach for the object and another for the background. You can set the threshold in between the object and background.
Teach-in Value
The Master
Dimensions
Ü 0
from conveyor surface
Output
How to trace the sensing !
DSA amplifiers (except DSA-M D-M8)
DSA-M D-M8
Teach with the target
Teach the background
DC
The threshold is between the target and the background.
2 "E
Master Slave Master Slave
1000 - 200 = 800 1100 - 300 = 800
as the gap to be. It's ti
Master Slave 900 - 100 = 800
Its traceable !
□ □
Ï z±-
Transparency Teaching
Open angle approx. 180°
Open angle approx. 180°
06
This is for Retro Reflective type DSR-800.
Teach without the object so the sensor works around threshold, then DSR-800 will delete even transparent object like film, glass, bottle, etc
□ □
Il II L
( The same gap has been traced. )
» r-
H5t
jtj
«1
27.9 36.9
BEF-WLL170 /
64.5
[LiSq \ N/P34 M8 4pln Connector
0.6
0.6
Automatic Teaching
Master: 04 7core 2m Cable Master: 04 3core 2m Cable Slave: 04 5core 2m Cable Slave: 041 core 2m Cable
You don't have to stop the conveyor.
Possible to teach-in the object that are even on the run.
Counter Mode
input/ Output
Pin layout
Counter Mode:
An output comes only when the preset numbers are counted. (Max 999999)
DSA-M □ -M8
External Input---/ _
(
12 to 24 V DC —
4)-V'
(TV
— Control output
— OV
Options
Connector cable
BEF-EB01-W190
2M JCN-L
2M JCN-S
Fixture terminal
npn
pnp
DSA-MN / DSA-SN
DSA-MP/DSA-SP
18
a a
Zone Teaching
You can set the area that you want to detect.
Using UP/DOWN button, set the area within 10% of flexibility.
■ay,,,
threshold
DSA-MN-M8
DSA-M P-M8
5M JCN-5L 10M JCL-10L
5M JCN-5S 10M JCL-10S
Response time
Judgement Teaching
OK (Output OFF) Output 1
Output 2
mm
You can select sensing distance and response time upon your
applications. 'Example: DSD-100
DSA-MN3 / DSA-SN3
DSA-M P3 / DSA-SP3
This function is excusive for DSTA-200, measurement type amplifier.
Used for judging size and width of object in the range of 10% allowance. Regaradless of position you can detect object, so it is actually Area Teach.
I STE-WLL190-05P |
Amplifier connector for power supply
I STE-WLL190-03P |
Detention connector for M8 connector type
(Response)
Response time 2msec
500ns
60us
. Bigger +/+10% Smaler-/-10%
+/-1u70 than the I than the
size. preset size.
Long Mode: Standard Mode:
Fast Mode :
DSA-SD/ DSA-SD3 of the slave amplifiers do not have power wires (brown, blue) as they receive the power supply from the base unit.
1000mm (Distance)
3