Digital amplifier with modular laser optics
By fitting Lens Attachment, you can select the beam of sensor amang Area beam, Line beam, or Spot Beam. Master and Slave Amplifiers for wire savings.
4-20mA output available for displacement sensing applications.
Inter-connected up to 30 pes. Parallel installation up to 50 pes.
(Thru-beam type)
DSA-M amplifier
e-con, the easy connection
Just snap-in the e-con to connect to amplifiers. All the sensor heads are connectable to any amplifier with the preset e-con mechanics.
7971
Applications
IP67 water tightness
All the DS Series sensor heads secures IP67 Water tightness with its rugged housing.
DSR-800
for monitoring meandering Transparent Film
DSR-800
for sensing transparent bag of cookies.
Edge of plastic bag is sometimes shrinked that is not good for stable sensing.
DSR-800 with Beam Selector BL-W130L-1 will provide a line beam that can work stably for such kind of object.
of
DSR-800 rsensor head
Install two pes of DSR-800 not touching the both edge of film. DSR-800 lets you know as soon as the beam touches the edge.
SENSOR HEAD LINEUP (All IP67 protection. All visible red laser for easy alignment.)
DSD-100
for sensing thread inside the bolt.
DSD-100 can focus on 1mm spot in 1 meter distance. As being designed in Coaxial optics, it can look in the depth of bolt.
DSTA-200
for finding a fine chip vacuumed by picker.
The line beam of 30mm width doesn't matter the position of object as far as it's in the 30mm range.
Retro Reflective Type
You can select the beam of 2mm spot, Area beam, or Line beam by changing optional Lens Attachment BL-W130L-1.
DSR-5000 senses Max 70 meter at its Long Distance Mode. Distance is varied upon Response time you will need, (see Page3)
DSR-800 senses 8 meter even for glass and PET bottle application. Both types can give minimum spot of 2mm size at 2 meter distance.
DSR-800 with Line Beam of 40 X 1mm (at 300mm distance) You need to attach BL-W130L-1 Lens attachment
DSR-800 with Area Beam of 35 X 35mm (at 300mm distance)
You need to attach BL-W130L-1 Lens attachment
DSR-800 (8 meter) and DSR-5000 (70 meter) with 2mm round spot (at 2 meter distance).
Diffuse Reflective Type
Max 1.5 meter distance at Long Mode. Coaxial spot beam Is given for accurate sensing, so you don't have to mind orientation of workpiece.
1mm spot size at 1 meter distance, that is convenient for sensing over the nitch of wall.
Sensor head and Amplifier List
Sensor head
2CH Amplifier
Type
Model
Mode
Sensing Distance
DSR-800 (Reflector MP45)
Long
8 meter (remark 1)
Standard
5 meter
Retro
Fast
2 meter
Reflective
DSR-5000 (Reflector P250F)
Long
0.5 - 50 meter (remark 2)
Standard
0.3 - 35 meter
Fast
0.1 - 20 meter
Diffuse Reflecrive
Long
1.5 meter
DSD-100
Standard
0.7 meter
Fast
0.25 meter
Thru-beam Cable type
DSTC-200
Standard
2 meter
DSTA-200
Standard
2 meter
Measurement
0.5 meter
Thru-beam M8 QD type
DSTC-200-M8
Standard
2 meter
DSTA-200-M8
Standard
2 meter
Measurement
0.5 meter
Mode
Specifications
DSA-MN
2CH, NPN Master Amplifier, 6 wires
DSA-MP
2CH, PNP Master Amplifier, 6 wires
DSA-SN
2CH, NPN Slave Amplifier, 4 wires
DSA-SP
2CH, PNP Slave Amplifier, 4 wires
1CH Amplifier
Mode
Specifications
DSA-MN3
1CH, NPN Master Amplifier, 3 wires
DSA-MP3
1CH, PNP Master Amplifier, 3 wires
DSA-SN1
1CH, NPN Slave Amplifier, 1 wire
DSA-SP1
1CH, PNP Slave Amplifier, 1 wire
DSA-MN-M8
M8QD, 1CH, NPN Master Amplifier, 4pins
DSA-MP-M8
M8QD, 1CH, PNP Master Amplifier, 4pins
DSD-100, coaxial small spot size of 1mm round.
Through Beam Type
You will select either DSTC-200 (2mm spot size) or DSTA-200 (Measurement Type that can provide 30 X 2.5mm of line beam as well as 4-20mA
analogue signal). M8 QD Connection is
I
Remark(1) Use of Lens Attachment for Line/Area beam for DSR-800 will change the sensing distance. Please see Page 5.
Remark(2) The distance in the Long Distance Mode of Retro Reflective Types will be extended at Sensitivity Compensation Status.
DSR-800 : 0.2-20 meter
DSR-5000 : 1 - 70 meter Remark(3) The distance of DSD-100 Is defined with 200 X 200 mm white paper.
availble for easy maintenance by using QD cable DSL-8L04-2-130.
DSL-8L04-2-130, M8 QD cable for sensor head DSTA(C)-200-M8
DSTA-200, Line Beam of 30 X 2.5mm in the distance of 50cm.
DSTC-200, Standard Thru-beam of 2mm spot size at 2m distance.