Amplifiers Regular Types
For Heads CD4A-30 / 85-350 and also for their High Power 3R types • CD4A-N (NPN)
Input / Output diagram
Zero reset
NPN model bank input Hold input Zero reset input 12-24VDC
— Ground
— Analog current output
— Analog voltage output
^ Alarm output
GND
la...
Zero reset input terminal
Hold input terminal
Bank input terminal
Sensor head A
NPN model control output Alarm output
ANG
• CD4A-A (PNP)
Specular Type
For Head CD4-L25
• CD4A-LN (NPN)
• CD4A-LA (PNP)
For Regular types
For Specular types
CAUTION
UJJHUIMIP.1. - If W [r.Wf IT "i ISh
o GND
NPN input GND
Output control terminals (5 lines)
-UJ.Z iiiv. i- na. h
*T: y 'S*.\t. li- -
— Empty
— Analog current output
— Analog voltage output
— Ground
r[mA) ANG
GND
Sensor head
b L
Uns Vin < ÏI ■
"~I Power supply terminal
Analog output (A/E) 12-24VDC
Class 2 (IEC/JIS) Class II (FDA)
Class 1 (IEC/JIS) Class II (FDA)
Zero reset input
Zero reset of single sensor (either A or B) Is activated with input of 10 ms or more, and deactivated with 500 ms or more. Zero reset of calculation reset Is activated with simultaneous input from sensor A and B, and deactivated with simultaneous Input of 500 ms or more. (For "simultaneous" input, the time difference between sensor A and B inputs should be within 10 ms.)
CO
:em
rcu
c
Ü
Dimensions
-o Current output
T
mi-im_J
-o Voltage output
7f^-0 GND
H<22 »I
27.4
27.A
Parts identifications
2d
© Setting value of Sensor Head A © Setting value of Sensor Head B
(D Calculation result processed according to the Calculation function setting
@ Output status of the output contorl (output 1,2,3,4,5)
© Bank number
© Displays the laser emission status of each sensor. ON : During laser emission, OFF : No laser emission.
® Lock indicator
© UP / DOWN buttons
Press to select the setting items.
© RIGHT / LEFT buttons
Press to select the function display or charge the setting items.
® Digit Position button
Press to change the digit position of the setting items with a wide range of setting value. (Activated only in Setup mode.)
(Q) Bank Selection button
Press to select the bank containing the programmed
measurement settings.
You can store up to eight(8) programs.
© Lock button
Press and hold for one(1) second or more to lock the button operation.
*The backlights of the operation buttons turn off during Lock status.
© Zero reset input
Press and hold one(1) second or more to preform zero reset of the sensor head (A or B). Press and hold again for two(2) seconds or more to cansel the function.
Simulataneous pressing of the buttons A and B resets the calculation result (CAL).
Press and hold simultaneously for one(1) second or more to cancel the function.
® Mode Selection button
Press to switch the display mode.
Specification
CD4A-N, CD4A-LN (NPN output type)
CD4A-P, CD4A-LP (PNP output type)
Number of connected sensor heads
Max. 2 pes
Sampling frequency
100 us
Supply voltage
12 to 24V, DC± 10%
Power consumption
270 mA/24 V (When connected with 2 sensor heads. Including analog current output)
Temperature drift
±0.01 % F.S/C
Analog output
ANG (V) [A][B]
Voltage output ±5 V/F.S. (Output impedance 100ft, resolution 1 mV)
ANG(mA) [A][B]
Current output 4 to 20 mA/F.S. (Load Impedance 300Q, resolution 1.5uA)
Alrm output
ALM A,ALM B
NPN open collector PNP open collector
Max. 100mA / DC 24V (residual voltage Max. 1.8 V)
Turns ON when the sensor head falls in measurement.
Control output
JDGE 1 to 5
NPN open collector PNP open collector
Max. 100mA / DC 24V (residual voltage Max. 1.8 V)
HI/LO setting for each line and Hysteresis setting are available.
Bank input
BANK 0 to 2
ON when connected to GND ON when connected to 12 to 24 V
8 banks selectable
Hold input
HOLD A, HOLD B, HOLD RST
ON when connected to GND ON when connected to 12 to 24 V
Laser off or measurement value holding (selectable In the menu)
Zero reset input
ZERO A, ZERO B
ON when connected to GND ON when connected to 12 to 24 V
Zero reset of Head A measurement valus / Head B measurement value / Calculation value Is available.
Optional features
Avarage sampling times, Filter mode (Cut-off frequency), Calculation, Hold setting, Output during alarm, Output control (Hysteresis), Analog output, Sensor head sensitivity control, Timer function, Memory function, Memory bank function, Auto zero reset
Display type
LCD display
Protection category
IP20
Operation temperature
-10 to +45"C (Non-condensing) / For strage : -20 to +60^
Operating humidity
35 to 85% RH / For strage: 35 to 85 % RH
Vibration resistance
10 to 55 Hz, Double amplitude 1.5mm, 2 h for XYZ axes
Shock resistance
20G (196m/s2)
Material
Chassis: Polycarbonatte, Terminal board: Nylon 66
Weight
240g (including terminal board)