| Response time is long. A SYNCHRO (synchronous input) may be set to "0 - 3." • It is necessary lo double (he response time when SYNCHRO is set to "0 - 3." Set it to "4" when not using any external synchronous signal. A IRESOLUT (resolution) may be set to "0." • The horizontal resolution becomes doubled as well as the response time when RESOLUT is set to "0." Normally, set it to " 1" if there is no problem. Indication area value is small. A MAXAREA (area maximum value) may be set to a value less than "9999." • Normally, set it to "9999." The value set here becomes the area maximum value. Set value cannot be changed. A The set value may be locked. ■ The set value is locked (change prohibited) VV!f9Y^^V Vf9V w hen indicated in blue. To release the ■lWjP*TK'^fiE»« lucked condition, display the corresponding P9f^Hr^Bl^VPvi set item on the Set Value Reference screen, ^gf^^^^^^^^^^^ and press and ^№ simultaneously for 3 seconds or more. |