| External teaching cannot be executed. f-L BANK (bank selection) may be set to "17." • Set it to "0 - 16"to enable external teaching. G External bank input does not work. A BANK (bank selection) may be set to "0 - 15." • Set it to "16" or "17" to utilize the external bank input. A SYNCHRO (synchronous input) may be set to "0 - 3." • Bank switch 3 input becomes a synchronous input when SYNCHRO is set to "0-3." Normally set it to "4." A OUTSDE (outside area range) may be set to "2" or "3." • Bank switch 1 input becomes an output signal within the area lower limit range when OUTSIDE is set to "2" or "3." Normally, set it to 0." t, Image of moving work is unstable blurred. f-L The shutter time may be long since BRIGHT (brightness) is set to a great value. • Perform teaching again after setting COLRFIL (color filter) to "2" or "3" to increase the sensitivity. • Perform teaching again after setting TEACHMD (teaching mode) to "2 (normal)" or "3 (teaching for dirty condition) to reduce the set value of BRIGHT (brightness). C Area varies depending on the moving speed of work. §-k The shutters open or close in sequence from the right to the left in the screen. Therefore, area becomes greater if the work flows from the right to the left and it becomes smaller if work flows from the left to the right. • Mount this device so that work flows in the vertical (up and down) direction in the screen. By doing so, the area hardly changes although the imaged work inclines. |