TROUBLESHOOTING
(r, Color cannot be correctly detected by teaching.
f-t TEACHMD (teaching mode) may be set to "1" or "3."
• Normally, set it to "0."
The teaching window may be too large, protruding beyond the color to be detected.
• Display F^SIZEl or E'SIZEl in the Teaching Setting screen, and reduce the size of the teaching window by pressing ^jjf.
See "1-point Teaching" on Pagel4.
f-k The set value of TEACH% (teaching color margin) may be too great, enlarging the color selection range.
• Normally, set it to "10" to "20. "
Lighting may be OFF.
• Set LIGHT (lighting control) to 1 or add an external lighting.
fi-k Is there any white reference object at the right edge of the screen when COLRFIL (color filter) is set to "1"?
• Place a white object (not shiny object) at the right edge of the screen.
The set value of KIL BLK (darkness correction factor) may be extremely great.
• When COLRFIL (color filter) is set to "0" or "2" and the value of KILBLK is too great, everything becomes white when black and gray are detected.
31
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
pdf-page pdf di En 2008-12-49-05