| *6: Brightness changes when RESOLUT is changed. In such a case, perform teaching again. Note that the output signal may turn ON/OFF momentarily when this set value is changed. *7: • When SYNCHRO is set to "1" or "3" one image taken immediately after the switch is operated is not displayed. However, the judgment output signal is effective. Also, the right-most column in the screen is displayed at the very left. This is only a problem of the screen display, and image is displayed normally when an image is taken. • When SYNCHRO is set to "0" or "2" and the bank switch 3 input width (0 is OFF width, 2 is ON width) is less than the response time, an image is displayed on the screen (including present area) once per twice, but the output signal is renewed every time. • When SYNCHRO set value is changed, an image may remain on the image screen. The screen is displayed normally when the screen is renewed by taking an image. |