Technical Data
Sensor AF16-N
Material:
measuring cell made of stainless steel SS 316 Ti, 1.4571 (standard)
Special materials:
SS 316 L (1.4435), 1.4539, 1.4462, TFM 4215, Hastelloy®C4, Hastelloy®C22, Titanium, Tantalum, Monel®400, Inconel® 625, PR and others on request.
Line size:
№ to 8", (DN 6 to DN 200) Process connections:
ASME Flange, DIN Flange, Varivent, JIS Flange, Tri-Clamp, BBS-Clamp, Female Thread NPT, Female Thread DIN ISO 228/1 G, SanitaryThread (DIN 11851), and others on request.
Gaskets:
Viton®, EPDM (FDA), EPDM (USP Class VI), Kalrez®, Chemraz®, Fluoraz®, Buna (NBR), Silicone, Viton®/FEP (FDA), and others on request.
Windows:
Pyrex®, Sapphire
Optical path length:
1 mm - 1000 mm
Process pressure:
10 mbarto 325 bar, (0.15 psi to 4713 psi), depending on process connection, material and design
Process temperature:
values are only valid with appropriate material of sensor body and gaskets. No icing on sensor!
• permanent: 0 °C to +120 °C, (+32 °F to +248 °F)
• peak (15 min/day): 0 °C to +150 °C, (+32 °F to +302 °f)
Ambient temperature:
• operation: 0 °C to +40 °C, (+32 °F to +104 °F)
(elevated or reduced ambient temperatures may require restrictions to the operating temperatures stated above!)
• transport: -20 °C to +70 °C, (-4 °F to +158 °F)
AirPurge:
connectors available as standard
Light source:
incandescent tungsten lamp: 5.0 V DC, 775 mA, typical lamp life 3to5 years
Wavelength range:
730 nm - 970 nm
Detector:
silicon photo diode, hermetically sealed Calibration:
basic calibration in CU (concentration units)
Measuring range:
any measuring range between 0 - 0.05 to 5 CU
Resolution:
< ± 0.05 % of respective measuring range Repeatability:
< ± 0.5 % of respective measuring range Linearity:
specific to application, < ± 1% of respective measuring range Protection:
all optical parts protected accordingto NEMA 4X (IP65) Cable lengths:
standard: 5, 10, 20, 35, 50 m, (16, 33, 66, 115, 164 ft.) maximum: 250 m, (800 ft.)
VA-plug-protection:
special ultra-shielded cable sets, optional rigid stainless steel connector
Certificates:
ISO 9001:2000, ATEX, FM, PED, CE, HP0
Use with C4000 Converters
Options
AF16-HT-N
high temperature model permanent:
-20 °C to +240 °C, (-4 °F to +464 °F) peak (15 min/day):
-20 °C to +260 °C, (-4 °F to +500 °F) Validation adapter
modularadapterwith application specific validation filter for sensor verification
AF16-EX-N and AF16-EX-HT-N
ATEX and FM ex-proof versions for safety and confidence in all hazardous area classification, Approval report: DMT ATEX E176, FMG J.I. 3013884 (please contact us for separate data sheet)
Measuring cells for any application
optek-Danulat GmbH "
Emscherbruchallee 2 45356 Essen Germany
Phone: +49-(0)201-63409-0 Fax: +49-(0)201-63409-999 E-Mail: info@optek.de Homepage: www.optek.com
optek-Danulat bv
Grote Brugse Grintweg 12 4005 AH Tiel Netherlands
Phone: +31-(0)344-683-800 Fax: +31-(0)344-653-950 E-Mail: info@optek.nl Homepage: www.optek.com
optek-Danulat, Inc.
N 118 W 18748 Bunsen Drive Germantown, Wl 53022, USA Phone: +1-262-437-3600 Fax: +1-262-437-3699 Tollfree: +1-800-371-4288 E-Mail: info@optek.com Homepage: www.optek.com