NX-SL/SI/SO
20Pages

{{requestButtons}}

Catalog excerpts

NX-SL/SI/SO - 1

NX-series Safety Control Units Integration of Safety into Machine Automation Enables Simple, Flexible System Configuration. • EN ISO13849-1 (PLe/Safety Category4), IEC 61508 (SIL3) certified. • One connection using Safety over EtherCAT (FSoE) * protocol enables flexible configuration by mixing the Safety Units with standard NX I/O. • Hardware and safety circuits can be configured using the Sysmac Studio (Ver. 1.07) For the most recent information on models that have been certified for safety standards, refer to your OMRON website. * Safety over EtherCAT (FSoE): The open protocol Safety over EtherCAT (abbreviated with FSoE "FailSafe over EtherCAT") defines a safety related communication layer for EtherCAT. Safety over EtherCAT meets the requirements of IEC 61508 SIL 3 and enables the transfer of safe and standard information on the same communication system without limitations with regard to transfer speed and cycle time. Features • Integrated safety into machine automation possible by connecting with the NX-series EtherCAT Coupler. • The Safety CPU Unit controls up to 128 Safety I/O Units. • 4 or 8 points per Safety Input Unit. The 4-point Safety Input Unit can be directly connected with OMRON Non-contact Switches and Singlebeam Sensors. • 2 or 4 points per Safety Output Unit. The 2-point Safety Output Unit is characterized by large output breaking current of 2.0 A. • The Safety Units can be freely allocated in any combination with standard NX I/O. • Compliant with IEC61131-3 • Safety programs can be standardized and reused efficiently by using POUs for design and operation. Sysmac is a trademark or registered trademark of OMRON Corporation in Japan and other countries for OMRON factory automation products. EtherCAT is registered trademark and patented technology, licensed by Beckhoff Automation Gmbh, Germany. Safety over EtherCAT is registered trademark and patented technology, licensed by Beckhoff Automation Gmbh, Germany. ODVA, CIPTM, CompoNetTM, DeviceNetTM, EtherNet/IPTM, and CIP SafetyTM are trademarks of ODVA. Other company names and product names in this document are the trademarks or registered trademarks of their res

Open the catalog to page 1
NX-SL/SI/SO - 2

System Configuration EtherCAT System Sysmac Studio Support Software EtherCAT master* NJ/NX-series CPU Unit Connection to peripheral USB port or built-in EtherNet/IP port on NJ-series CPU Unit Built-in EtherCAT port Sysmac Studio Support Software ●EtherCAT Slave Terminal Communications cable Ethernet cables Peripheral USB port. NX Series EtherCAT Coupler Unit NX-ECC201/ECC202 Safety CPU Unit NX-SL3300 NX-SL3500 Safety Input Unit NX-SID800 Connection to peripheral USB port on EtherCAT Coupler Unit NX Series EtherCAT Coupler Unit NX-ECC201 Safety Output Unit NX-SOD400 Safety Input Unit...

Open the catalog to page 2
NX-SL/SI/SO - 3

NX-SL/SI/SO Stand-alone System EtherNet/IP master CJ-series CPU Unit or master from another manufacturer Peripheral USB port EtherNet/IP port Communications cable Ethernet cables Sysmac Studio Support Software NX-series EtherNet/IP Coupler Unit NX-EIC202 Safety CPU Unit NX-SL3300 Safety Input Unit NX-SID800/SIH400 Safety Output Unit NX-SOD400/SOH200 End Cover NX Units * Connection to peripheral USB port on EtherNet/IP Coupler Unit * Refer to NX-series EtherNet/IPTM Coupler Unit Datasheet for the NX Units that can be connected to the NX-series EtherNet/IP Coupler Unit.

Open the catalog to page 3
NX-SL/SI/SO - 4

Ordering Information Safety CPU Unit

Open the catalog to page 4
NX-SL/SI/SO - 5

NX-series Communications Coupler Units Product name Note: For details, refer to your local OMRON website. *1 One End Cover NX-END01 is provided with the NX-series Communications Coupler Units. *2 This depends on the specifications of the EtherCAT master. For example, the values are as follows when the EtherCAT Coupler Unit is connected to the built-in EtherCAT port on an NJ5-series CPU Unit: 500 ps, 1,000 ps, 2,000 ps, and 4,000 ps. Refer to the NJ/NX-series CPU Unit Built-in EtherCAT Port User's Manual (Cat. No. W505) for the specifications of the built-in EtherCAT ports on NJ/NX-series...

Open the catalog to page 5
NX-SL/SI/SO - 6

NX-series Safety Control Units NX-SL3/SI/SO

Open the catalog to page 6
NX-SL/SI/SO - 7

Specifications of Individual Units

Open the catalog to page 7
NX-SL/SI/SO - 8

Safety Input Units NX-SIH400/SID800 Unit name Free-Run refreshing Screwless clamping terminal block (8 terminals) 1.2 V max. (Between IOV and all output terminals) Photocoupler isolation 20 MQ min. between isolated circuits (at 100 VDC) Power supplied from the NX bus Terminal block Si0 to Si3: Safety input terminals T0 and T1: Test output terminals Refer to User's manual (Cat.No.Z930) for details. Safety Input Unit NX-SID800 NX-SL/SI/SO Screwless clamping terminal block (16 terminals) 510 VAC for 1 min between isolated circuits, leakage current: 5 mA max. Connected to a CPU Unit or a...

Open the catalog to page 8
NX-SL/SI/SO - 9

Unit name 2.0 A/point 4.0 A/Unit at 40°C 2.5 A/Unit at 55°C The maximum load current depends on the installation orientation and ambient temperature Free-Run refreshing Screwless clamping terminal block (8 terminals) 1.2 V max. (Between IOV and all output terminals) 2 V max. (Between IOG and all output terminals) Photocoupler isolation 20 MQ min. between isolated circuits (at 100 VDC) Power supplied from the NX bus So0 and So1: Safety output terminals IOG: I/O power supply 0 V Refer to User's manual (Cat.No.Z930) for details. Safety Output Unit 510 VAC for 1 min between isolated circuits,...

Open the catalog to page 9
NX-SL/SI/SO - 10

Unit name Model Safety Output Unit NX- SOH200 Installation orientation: • Connected to a CPU Unit or a Communication Control Unit Possible in the upright installation orientation. • Connected to a Communications Coupler Unit 6 possible orientations Restrictions: For upright installation, the ambient temperature is restricted as shown below depending on the total Unit load current. Installation orientation: • Connected to a CPU Unit or a Communication Control Unit Possible in the upright installation orientation. • Connected to a Communications Coupler Unit 6 possible orientations...

Open the catalog to page 10
NX-SL/SI/SO - 11

Function Specifications

Open the catalog to page 11
NX-SL/SI/SO - 12

Note: Supported only by the Sysmac Studio version 1.07 or higher. *1. Supported only by the Sysmac Studio version 1.24 or higher. *2. Supported if the EtherNet/IP Coupler is selected with Sysmac Studio version 1.11 or higher. *3. Supported only by the Sysmac Studio version 1.12 or higher. *4. Supported only by the Sysmac Studio version 1.17 or higher. *5. Supported only by the Sysmac Studio version 1.08 or higher. *6. Supported only by the Sysmac Studio version 1.10 or higher. *7. Supported only by the Sysmac Studio...

Open the catalog to page 12

All OMRON catalogs and technical brochures

  1. D4F

    8 Pages

  2. D4GS-N

    11 Pages

  3. E4E2

    5 Pages

  4. G9SE Series

    20 Pages

  5. G9SP

    28 Pages

  6. G9SX-SM

    24 Pages

  7. G9SX-SM/LM

    9 Pages

  8. G9SX/G9SX-GS

    49 Pages

  9. G9SX-LM

    28 Pages

  10. G9SB

    10 Pages

  11. G9SA

    16 Pages

  12. DST1 Series

    5 Pages

  13. WS02-CFSC1-E

    3 Pages

  14. G9SA-300-SC

    9 Pages

  15. K8AK-AS

    12 Pages

  16. K8AK-AW

    16 Pages

  17. K8AK-VS

    12 Pages

  18. K8AK-VW

    12 Pages

  19. K8AK-PH

    12 Pages

  20. K8DS-PH

    12 Pages

  21. K8AK-PM

    16 Pages

  22. K8DS-PM

    12 Pages

  23. K8AK-PA

    12 Pages

  24. K8DS-PA

    12 Pages

  25. K8AK-PW

    12 Pages

  26. K8DS-PU

    12 Pages

  27. K8DS-PZ

    12 Pages

  28. K8AK-TS/PT

    12 Pages

  29. K8AK-LS

    12 Pages

  30. K8AK-TH

    12 Pages

  31. K2CM

    16 Pages

  32. SE

    15 Pages

  33. SAO

    13 Pages

  34. APR-S

    6 Pages

  35. XS5

    25 Pages

  36. XS2

    29 Pages

  37. F92A

    4 Pages

  38. GLS

    3 Pages

  39. TL-L

    5 Pages

  40. V680 series

    68 Pages

  41. V680S Series

    68 Pages

  42. MY

    35 Pages

  43. E3NC-L/-S

    16 Pages

  44. NE0A-SCPU01

    6 Pages

  45. LY

    14 Pages

  46. G2R-[]-S

    11 Pages

  47. G7T

    7 Pages

  48. G2A

    9 Pages

  49. G2A-434

    7 Pages

  50. G2AK

    7 Pages

  51. MK-S

    9 Pages

  52. MK-S(X)

    12 Pages

  53. MM

    17 Pages

  54. MMK

    14 Pages

  55. G4Q

    6 Pages

  56. G7Z

    9 Pages

  57. G7J

    10 Pages

  58. E4B

    12 Pages

  59. E4A-3K

    9 Pages

  60. E4C-UDA

    5 Pages

  61. E6H-C

    5 Pages

  62. E6F-C

    5 Pages

  63. E6D-C

    5 Pages

  64. E6B2-C

    5 Pages

  65. E6A2-C

    5 Pages

  66. NL

    8 Pages

  67. VB

    5 Pages

  68. SC

    5 Pages

  69. D5F

    5 Pages

  70. D5A

    8 Pages

  71. E3S-GS3E4

    3 Pages

  72. E3S-R

    11 Pages

  73. E3S-A

    21 Pages

  74. E3S-CL

    9 Pages

  75. E3ZM-C

    14 Pages

  76. E3T Data Sheet

    26 Pages

  77. E3T Series

    6 Pages

  78. G5 Series

    59 Pages

  79. Sysmac Catalog

    410 Pages

  80. VT-X700

    6 Pages

  81. E5AC-T

    8 Pages

  82. CP1

    12 Pages

  83. CP1E

    12 Pages

  84. MS4800

    40 Pages

  85. VC-DL100

    6 Pages

  86. FZ4 Series

    42 Pages

  87. ZG2

    16 Pages

  88. ZS Series

    32 Pages

  89. ZW Series

    24 Pages

  90. E9NC-T

    2 Pages

  91. CompoNet

    28 Pages

  92. NT series

    18 Pages

  93. E2EF

    8 Pages

Archived catalogs

  1. Vision Systems

    20 Pages