MM - 1

Power Relay Stable Contact Reliability and Long Life • Easy to mount, wire, and use. • A large selection of models including various contact forms, DC-switching models, and open models. • Mechanical life: 5,000,000 operations; electrical life (under rated load): 500,000 operations. • Models also available with built-in diodes and for use as auxiliary power relays. Refer to Safety Precautions for All Relays. Ordering Information Type Contact form Open structure Solder terminals Screw terminals Plug-in (octal pins) terminals 4PDT DC-switching with built-in diode With built-in diode With operation indicator DC-switching with operation indicator Conforming to auxiliary power relay speci- 4PDT fications ■ Available Models Open Coils (with Solder Terminals) Type Standard Contact form Relay model Available rated voltage

Open the catalog to page 1
MM - 2

MM Open Coils (with Screw Terminals) Type Standard Contact form Relay model Available rated voltage Cased Coils (Plug-in Terminals) Type Standard Contact form Relay model Available rated voltage With built-in diode DC-switching with built-in diode With operation indicator Conforming to auxiliary power relay specifications Conforming to auxiliary power relay specifications for DC-switching DC-switching with operation indicator Models Conforming to Auxiliary Power Relay Specifications The MM4P-JD and MM4XP-JD satisfy the ratings of auxiliary relays provided in JEC-2500 (1987) standards for...

Open the catalog to page 2
MM - 3

MM Model Number Legend MM@@@@-@ 1 4. Operation Indicator None: Not provided N: Provided 5. Built-in Diode None: Not provided D: Provided 1. Contact Form 2: DPDT 3: 3PDT 4: 4PDT 2. Type (See Note.) None: Standard X: DC-switching 3. Terminal Shape None: Solder B: Screw P: Plug-in Note: The suffix “JD” indicates models conforming to auxiliary power relay specifications. ■ Accessories (Order Separately) Mounting Brackets Mounting Bracket (S bracket) Sockets Relay model DIN Track/Front-connecting Socket (screw terminals) Back-connecting Socket (solder terminals)

Open the catalog to page 3
MM - 4

Specifications ■ Coil Ratings Open Coils (with Solder or Screw Terminals) Rated voltage (V) Mustrelease voltage Mustoperate voltage Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/–20% for AC rated current and ±15% for DC coil resistance. 2. The AC coil resistance values are reference values. 3. Performance characteristic data are measured at a coil temperature of 23°C. 4. The maximum voltage is one that is applicable instantaneously to the Relay coil at an ambient temperature of 23°C and not continuously. Cased Coils...

Open the catalog to page 4
MM - 5

MM Coils (Conforming to Auxiliary Power Relay Specifications) Rated voltage (V) Coil Coil inductance (H) resistance (Ω) Contact release Contact operate Opera- Power consumption tion level (VA or W) (JEC174D) Initial Rated Mustrelease voltage Mustoperate voltage B Hot start after coil heated Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/–20% for AC rated current and ±15% for DC coil resistance. 2. The AC coil resistance and coil inductance values are for reference only. 3. Performance characteristic data are measured at a...

Open the catalog to page 5
MM - 6

MM Contacts (Conforming to Auxiliary Power Relay Specifications) Item Inductive load (cosφ = 0.4, L/R = 7 ms) Contact type Rated load Rated carry current Max. switching power (reference value) Inductive load (cosφ = 0.4, L/R = 7 ms) Contact material Resistive load Note: 1. A model for DC loads is not in stable operation when switching an inductive load within a operating current range between 0.5 and 2.5 A at a minimum of 125 VDC, where the load cannot be switched. 2. If L/R exceeds 7 ms when switching DC inductive loads, an arc-breaking time of up to 50 ms must be considered in application...

Open the catalog to page 6
MM - 7

MM Relays (Conforming to Auxiliary Power Relay Specifications) Item Cased Relays Contact resistance (See note 2.) Operate time (See note 3.) Release time (See note 3.) Mechanical: Electrical: 1,800 operations/hr 1,800 operations/hr (under rated load) Insulation resistance (See note 4.) Dielectric strength Between coil and contact: 2,000 VAC, 50/60 Hz for 1 minute Between contacts of different polarity: 2,000 VAC, 50/60 Hz for 1 minute Between contacts of same polarity: 1,500 VAC, 50/60 Hz for 1 minute Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm...

Open the catalog to page 7
MM - 8

MM Endurance Curves Open Relays Cased Relays MM@P(N, -D) 220 VAC resistive load inductive load (cosφ = 0.4) 24 VDC resistive load inductive load L/R = 7 ms 5,000 220 VAC resistive load inductive load (cosφ = 0.4) 24 VDC resistive load inductive load L/R = 7 ms ■ DC-switching Relays Maximum Switching Power Open Relays Cased Relays Endurance Curves Open Relays Cased Relays 24 VDC resistive load 110 VDC resistive load 24 VDC resistive load 110 VDC resistive load

Open the catalog to page 8
MM - 9

■ Relays Conforming to Auxiliary Power Relay Specifications Maximum Switching Power

Open the catalog to page 9
MM - 10

MM Ambient Temperature vs. Must-operate and Must-release Voltage MM2P DC Must-operate voltage Must-release voltage Must-operate and reset voltage (%) Must-operate and reset voltage (%) Must-operate voltage Must-release voltage Ambient Temperature vs. Coil Temperature Rise MM2P DC Coil temperature rise (° C) Coil temperature rise ( ° C) MM2P 110 VAC (60 Hz) Contact carry current Contact carry current Contact Reliability (Improved Allen-Bradley Test Circuit) Number of samples: 5 Measurement conditions: Impose a shock of 100 m/s2 in the ±X, ±Y, and ±Z directions three times each with the Relay...

Open the catalog to page 10
MM - 11

MM Relay Mounting Adjacent Distance vs. Coil Temperature Rise Coil temperature rise ( ° C) MM4P 100 /(110) VAC Relay mounting position Condition: The saturated coil temperature is measured with the rated carry current (7.5 A) at the rated coil voltage (100 VAC at 50 Hz). Contact carry current (7.5 A) No contact carry current Average of No. 2, 4, 6, and 8 Average of No. 1, 3, 7, and 9 Mounting adjacent distance l (mm) Dimensions Note: All units are in millimeters unless otherwise indicated. ■ Standard Relays Open Relays Solder Terminals MM2(X), MM4(X), MM3(X) Four, M4 mounting screw holes...

Open the catalog to page 11

All OMRON catalogs and technical brochures

  1. D4F

    8 Pages

  2. D4GS-N

    11 Pages

  3. E4E2

    5 Pages

  4. G9SE Series

    20 Pages

  5. NX-SL/SI/SO

    20 Pages

  6. G9SP

    28 Pages

  7. G9SX-SM

    24 Pages

  8. G9SX-SM/LM

    9 Pages

  9. G9SX/G9SX-GS

    49 Pages

  10. G9SX-LM

    28 Pages

  11. G9SB

    10 Pages

  12. G9SA

    16 Pages

  13. DST1 Series

    5 Pages

  14. WS02-CFSC1-E

    3 Pages

  15. G9SA-300-SC

    9 Pages

  16. K8AK-AS

    12 Pages

  17. K8AK-AW

    16 Pages

  18. K8AK-VS

    12 Pages

  19. K8AK-VW

    12 Pages

  20. K8AK-PH

    12 Pages

  21. K8DS-PH

    12 Pages

  22. K8AK-PM

    16 Pages

  23. K8DS-PM

    12 Pages

  24. K8AK-PA

    12 Pages

  25. K8DS-PA

    12 Pages

  26. K8AK-PW

    12 Pages

  27. K8DS-PU

    12 Pages

  28. K8DS-PZ

    12 Pages

  29. K8AK-TS/PT

    12 Pages

  30. K8AK-LS

    12 Pages

  31. K8AK-TH

    12 Pages

  32. K2CM

    16 Pages

  33. SE

    15 Pages

  34. SAO

    13 Pages

  35. APR-S

    6 Pages

  36. XS5

    25 Pages

  37. XS2

    29 Pages

  38. F92A

    4 Pages

  39. GLS

    3 Pages

  40. TL-L

    5 Pages

  41. V680 series

    68 Pages

  42. V680S Series

    68 Pages

  43. MY

    35 Pages

  44. E3NC-L/-S

    16 Pages

  45. NE0A-SCPU01

    6 Pages

  46. LY

    14 Pages

  47. G2R-[]-S

    11 Pages

  48. G7T

    7 Pages

  49. G2A

    9 Pages

  50. G2A-434

    7 Pages

  51. G2AK

    7 Pages

  52. MK-S

    9 Pages

  53. MK-S(X)

    12 Pages

  54. MMK

    14 Pages

  55. G4Q

    6 Pages

  56. G7Z

    9 Pages

  57. G7J

    10 Pages

  58. E4B

    12 Pages

  59. E4A-3K

    9 Pages

  60. E4C-UDA

    5 Pages

  61. E6H-C

    5 Pages

  62. E6F-C

    5 Pages

  63. E6D-C

    5 Pages

  64. E6B2-C

    5 Pages

  65. E6A2-C

    5 Pages

  66. NL

    8 Pages

  67. VB

    5 Pages

  68. SC

    5 Pages

  69. D5F

    5 Pages

  70. D5A

    8 Pages

  71. E3S-GS3E4

    3 Pages

  72. E3S-R

    11 Pages

  73. E3S-A

    21 Pages

  74. E3S-CL

    9 Pages

  75. E3ZM-C

    14 Pages

  76. E3T Data Sheet

    26 Pages

  77. E3T Series

    6 Pages

  78. G5 Series

    59 Pages

  79. Sysmac Catalog

    410 Pages

  80. VT-X700

    6 Pages

  81. E5AC-T

    8 Pages

  82. CP1

    12 Pages

  83. CP1E

    12 Pages

  84. MS4800

    40 Pages

  85. VC-DL100

    6 Pages

  86. FZ4 Series

    42 Pages

  87. ZG2

    16 Pages

  88. ZS Series

    32 Pages

  89. ZW Series

    24 Pages

  90. E9NC-T

    2 Pages

  91. CompoNet

    28 Pages

  92. NT series

    18 Pages

  93. E2EF

    8 Pages

Archived catalogs

  1. Vision Systems

    20 Pages