G2AK
7Pages

{{requestButtons}}

Catalog excerpts

G2AK - 1

Latching Relay Magnetic Latching Version of G2A Ideal for Sequence Control • Double-winding latch system with continuous rating. • Terminals pulled from the respective junctions between the built-in diodes and set and reset coils allow the built-in diodes to be externally connected for coil surge absorption. • Excellent vibration/shock resistance with minimal secular decrease in latching power. • Easy monitoring of ON/OFF operation due to the built-in operation indicator mechanism. • Same outline dimensions as the standard models of G2A. Ordering Information Contact form Plug-in terminals Standard model Arc barrier equipped model Fully sealed model Note: 1. When placing your order, add the coil voltage rating to the model number as shown below. Example: G2AK-232A 100 VAC Rated coil voltage 2. The applicable rated voltage range can be increased by connecting an external resistor. Refer to Specifications for details. Model Number Legend G2AK-@@@@@ 1 1. Number of Poles (Contact Form) 2: DPDT 2. Contact Type 3: Crossbar bifurcated 3. Enclosure Construction 2: Casing 4: Fully sealed 4. Terminal Shape A: Plug-in terminal 1P: PCB terminal Arc barrier equipped model 5. Safety Breaking Mechanism None: No Y: Arc barrier Fully sealed model The arc barrier equipped model is a relay designed to prevent arc short- The fully sealed model is a relay in a gas-tight plastic enclosure and thus circuiting between phases and can be used in a circuit which has poten- exhibits stable performance in an adverse atmosphere of harmful gas, tial difference between phases. The switching power of such a circuit moisture, or powdery dust. with potential difference must be limited to less than 1/2 the rated load when using this Relay.

Open the catalog to page 1
G2AK - 2

G2AK ■ Accessories (Order Separately) Sockets Item Back-connecting Relay Screw terminals Solder terminals Wire-wrap terminals Without Hold-down Clip With Hold-down Clip Note: See the G2AK Datasheet for detailed information on the Relay Hold-down Clips and Socket Mounting Plates. Specifications ■ Coil Ratings Rated voltage Set coil Rated current 50 Hz Reset coil Coil resistance Coil resistance Power consumption Reset coil Reset voltage Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%, –20% for AC rated current and ±15% for DC...

Open the catalog to page 2
G2AK - 3

G2AK ■ Contact Ratings Load Resistive load (cosφ = 1) Contact type Contact material Movable: Au-clad AgPd Fixed: AgPd Rated load Rated carry current Inductive load (cosφ = 0.4) (L/R = 7 ms) Crossbar bifurcated ■ Characteristics Contact resistance (see note 2) Reset time (see note 3) Mechanical: 18,000 operations/hour Electrical: 1,800 operations/hour (under rated load) Insulation resistance (see note 4) 100 MΩ min. (at 500 VDC) Dielectric strength 1,500 VAC, 50/60 Hz for 1 minute between coil and contact (700 VAC between contacts of same pole) (1,000 VAC between set and reset coils)...

Open the catalog to page 3
G2AK - 4

Engineering Data Endurance Endurance (x10 3 operations) Maximum Switching Power AC resistive load AC inductive load (cosφ = 0.4) 24-VDC resistive load 24-VAC inductive load L/R = 7 ms 110-VAC resistive load 110-VAC inductive load (cosφ = 0.4) Malfunctioning Shock Not energized Energized Shock direction Number of samples = 5 Measurement conditions: Impose a shock of 100 m/s2 in the ±X, ±Y, and ±Z directions three times each with the Relay energized and not energized to check the shock values that cause the Relay to malfunction. Hold Force Attenuation vs. Elapsed Time Set voltage Reset...

Open the catalog to page 4
G2AK - 5

Dimensions Arc Barrier Equipped Models with Plug-in Terminals G2AK-232A(Y) Fourteen, 1.2-dia. holes x 3 elliptic holes Fully Sealed Models with Plug-in Terminals G2AK-234A Fourteen, 1.2-dia. holes x 3 elliptic holes 1 Terminal Arrangement/Internal Connections (Bottom View) Mounting Holes on PCB (Bottom View) Note: Dimensional tolerances are ±0.1 mm 5 Note: Terminals (Nos. 12 and 9) are pulled from the respective junctions between the diode and set coil and between the diode and reset coil. Use these terminals through external connection for selective use or non-use of the diodes as well as...

Open the catalog to page 5
G2AK - 6

Safety Precautions Refer to Safety Precautions for All Relays. The G2AK can be used for special purposes by utilizing its built-in diodes. When built-in diodes are not required • With the DC-coil Latching Relay, the built-in diodes become unnecessary for a circuit in which a coil operating switch is incorporated for each of the set and reset coils as shown on the right. * Unwanted diodes • With the DC/AC-coil Latching Relay, if the junctions between the set coil and built-in diode and between the reset coil and built-in diode are connected as shown on the right, only one of the built-in...

Open the catalog to page 6
G2AK - 7

Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER...

Open the catalog to page 7

All OMRON catalogs and technical brochures

  1. D4F

    8 Pages

  2. D4GS-N

    11 Pages

  3. E4E2

    5 Pages

  4. G9SE Series

    20 Pages

  5. NX-SL/SI/SO

    20 Pages

  6. G9SP

    28 Pages

  7. G9SX-SM

    24 Pages

  8. G9SX-SM/LM

    9 Pages

  9. G9SX/G9SX-GS

    49 Pages

  10. G9SX-LM

    28 Pages

  11. G9SB

    10 Pages

  12. G9SA

    16 Pages

  13. DST1 Series

    5 Pages

  14. WS02-CFSC1-E

    3 Pages

  15. G9SA-300-SC

    9 Pages

  16. K8AK-AS

    12 Pages

  17. K8AK-AW

    16 Pages

  18. K8AK-VS

    12 Pages

  19. K8AK-VW

    12 Pages

  20. K8AK-PH

    12 Pages

  21. K8DS-PH

    12 Pages

  22. K8AK-PM

    16 Pages

  23. K8DS-PM

    12 Pages

  24. K8AK-PA

    12 Pages

  25. K8DS-PA

    12 Pages

  26. K8AK-PW

    12 Pages

  27. K8DS-PU

    12 Pages

  28. K8DS-PZ

    12 Pages

  29. K8AK-TS/PT

    12 Pages

  30. K8AK-LS

    12 Pages

  31. K8AK-TH

    12 Pages

  32. K2CM

    16 Pages

  33. SE

    15 Pages

  34. SAO

    13 Pages

  35. APR-S

    6 Pages

  36. XS5

    25 Pages

  37. XS2

    29 Pages

  38. F92A

    4 Pages

  39. GLS

    3 Pages

  40. TL-L

    5 Pages

  41. V680 series

    68 Pages

  42. V680S Series

    68 Pages

  43. MY

    35 Pages

  44. E3NC-L/-S

    16 Pages

  45. NE0A-SCPU01

    6 Pages

  46. LY

    14 Pages

  47. G2R-[]-S

    11 Pages

  48. G7T

    7 Pages

  49. G2A

    9 Pages

  50. G2A-434

    7 Pages

  51. MK-S

    9 Pages

  52. MK-S(X)

    12 Pages

  53. MM

    17 Pages

  54. MMK

    14 Pages

  55. G4Q

    6 Pages

  56. G7Z

    9 Pages

  57. G7J

    10 Pages

  58. E4B

    12 Pages

  59. E4A-3K

    9 Pages

  60. E4C-UDA

    5 Pages

  61. E6H-C

    5 Pages

  62. E6F-C

    5 Pages

  63. E6D-C

    5 Pages

  64. E6B2-C

    5 Pages

  65. E6A2-C

    5 Pages

  66. NL

    8 Pages

  67. VB

    5 Pages

  68. SC

    5 Pages

  69. D5F

    5 Pages

  70. D5A

    8 Pages

  71. E3S-GS3E4

    3 Pages

  72. E3S-R

    11 Pages

  73. E3S-A

    21 Pages

  74. E3S-CL

    9 Pages

  75. E3ZM-C

    14 Pages

  76. E3T Data Sheet

    26 Pages

  77. E3T Series

    6 Pages

  78. G5 Series

    59 Pages

  79. Sysmac Catalog

    410 Pages

  80. VT-X700

    6 Pages

  81. E5AC-T

    8 Pages

  82. CP1

    12 Pages

  83. CP1E

    12 Pages

  84. MS4800

    40 Pages

  85. VC-DL100

    6 Pages

  86. FZ4 Series

    42 Pages

  87. ZG2

    16 Pages

  88. ZS Series

    32 Pages

  89. ZW Series

    24 Pages

  90. E9NC-T

    2 Pages

  91. CompoNet

    28 Pages

  92. NT series

    18 Pages

  93. E2EF

    8 Pages

Archived catalogs

  1. Vision Systems

    20 Pages