CompoNet
28Pages

{{requestButtons}}

Catalog excerpts

CompoNet - 1

Multi Vender Network for Sensors & Actuators

Open the catalog to page 1
CompoNet - 2

Microsoft, Visual Basic, Visual C++, and Windows are registered trademarks of the Microsoft Corporation in the USA and other countries. Other company names and product names in this document are the trademarks or registered trademarks of their respective companies.

Open the catalog to page 2
CompoNet - 3

New Products Support for Machine Automation Controller NJ-Series! Multi-function Compact Inverter MX2-Series CompoNet Communication Unit Support for open network The MX2 series* can be connected to CompoNet by mounting the Communications Unit. * Supported for the MX2 series Ver.1.1 or higher. 8 types of remote I/O higher functions 8 types of remote I/O functions that exchange I/O data automatically without program are provided. All of the following functions of the inverter can also be used. · Simple positioning control · Torque control · Setting of acceleration/deceleration time etc....

Open the catalog to page 3
CompoNet - 4

Manufacturing Site Moving into the Global Open Netwo Information layer Controller layer Device layer Sensor & Act A Actuator layer

Open the catalog to page 4
CompoNet - 5

The drastic changes to the environment faced by today's manufacturing industry has led a wide range of issues such as the standardization of system infrastructure and the shift to more advanced functions. In order to solve these issues, it is necessary to share on-site data, such as for product quality and how to respond to changes in the enviroment, to vertically start up devices utilizing this data and execute preventive maintenance universally and quickly. That is why attention is focusing on utilizing globally standardized "open networks" in the plant management layer, the control...

Open the catalog to page 5
CompoNet - 6

The conventional fast communication networks exceeding 10 Mbps must use special cables, which place restrictions on wiring. For example, they do not allow the connecting of branches. In order to be able to use regular cables with their easier wiring, the only choice is a low baud rate network. With conventional field networks, achieving a "high-speed" while maintaining "ease of wiring", "informatization", and "low cost" is difficult. CompoNet achieves these competing conflicting objectives thanks to the latest technology for raising the efficiency of communication lines. CompoNet makes it...

Open the catalog to page 6
CompoNet - 7

Fast Communication 1024 points in 1 ms: fastest class in the industry CompoNet solves the problems of conventional field networks! Wiring Superior branching Informatization Machine preventive maintenance Simple and Low-Cost Simple installation and regular cables mean lower cost

Open the catalog to page 7
CompoNet - 8

Fast Communication Fast multipoint communication reduces takt times Fastest class Communication Speeds in the Industry Provides the fastest communication speeds in the industry for a sensor-actuator level network. It is possible to send data consisting a large number of control points on multiple nodes. There is no response time delay, even with repeater units. 1,024 I/O points in 1 ms Up to 2,560 I/O points Up to 384 nodes Reduction in takt time Value when message communication is not executed. Fast Communication Technology even at Low Baud Rate of 4 Mbps Provides excellent performance in...

Open the catalog to page 8
CompoNet - 9

Superior branching adaptability reduces wiring work Flexible Installation Select the best branching method for your application. CompoNet provides both fast communication and easy wiring. Branch wiring is a powerful tool for installing large numbers of slaves in a variety of locations. You can optimize your cable layout to match the layout of your equipment. Distance can easily be extended. A maximum distance of 1500 m is possible (when baud rate is 93.75 kbps). Select the best branching method for your application Different types of cables can be used before and after repeater units Flat...

Open the catalog to page 9
CompoNet - 10

Reducing the start-up time and maintenance work with informatization CX-Integrator Makes Start-Up and Recovery Work More Efficient CX-Integrator software lets you set the PLC network/serial communication system configuration from a computer. CX-Integrator makes it easy to handle CompoNet assignment, parameter setting, connection state monitoring, comment setting, network diagnosis, etc. from a computer. Quick discovery of error locations Separate an error at a branch destination You can easily check the connection states of all the slaves and quickly specify error contents. You can check...

Open the catalog to page 10
CompoNet - 11

Slashes start-up workload and equipment cost! Flat Cable for Easy One-Touch Installation Flat cable shortens installation time. It also prevents connector installation mistakes. Flat cable Shield cable for field networks Slashes installation work to 1/30 of the required time! Peel away the cable coating. Take out the shield wire. Peel away the lead coating. Attach the 5 crimp terminals. Insert the cable and fasten with 5 screws. Insert the cable into the connector. Snap fit with tool. Smooth Start-Up with Simple Setup Just set the master baud rate and the slave node addresses and the system...

Open the catalog to page 11
CompoNet - 12

Network Specifications CompoNet is made up of segments divided by repeater unit. There are four CompoNet baud rates, from 4 Mbps ultra-fast mode to 93.75 kbps long-distance mode. The wiring specifications depend on the baud rate. Select the one that best matches your application. Master Unit Terminating Resistor 1st Repeater Repeater Slave Baud rate Cable type Round cable I, II Flat cable I Round cable I, II Flat cable I Trunk Line (Segment 1) Sub-Trunk Line (Segment 2) Sub-Trunk Line (Segment 3) Sub-Trunk Line (disabled) Branch Line Sub-Branch Line Multidrop T-branch Terminating Resistor...

Open the catalog to page 12
CompoNet - 13

Example of wiring for 4Mbps (Application: Ultra-fast communications) 30 meters x 3 segments (2 repeater stages) = 90 meters (maximum length) 30 meters (maximum length per segment) Master Unit Multidrop connection possible Terminating Resistor Repeater Flat cable I Round cable I and II can be used. Always connect a terminating resistor at the end of each trunk line and sub-trunk line. T-branch connections not possible from trunk lines and sub-trunk lines (Only multidrop connection possible) Example of wiring for 3Mbps (Application: Fast communications with branching) 30 meters x 3 segments...

Open the catalog to page 13

All OMRON catalogs and technical brochures

  1. D4F

    8 Pages

  2. D4GS-N

    11 Pages

  3. E4E2

    5 Pages

  4. G9SE Series

    20 Pages

  5. NX-SL/SI/SO

    20 Pages

  6. G9SP

    28 Pages

  7. G9SX-SM

    24 Pages

  8. G9SX-SM/LM

    9 Pages

  9. G9SX/G9SX-GS

    49 Pages

  10. G9SX-LM

    28 Pages

  11. G9SB

    10 Pages

  12. G9SA

    16 Pages

  13. DST1 Series

    5 Pages

  14. WS02-CFSC1-E

    3 Pages

  15. G9SA-300-SC

    9 Pages

  16. K8AK-AS

    12 Pages

  17. K8AK-AW

    16 Pages

  18. K8AK-VS

    12 Pages

  19. K8AK-VW

    12 Pages

  20. K8AK-PH

    12 Pages

  21. K8DS-PH

    12 Pages

  22. K8AK-PM

    16 Pages

  23. K8DS-PM

    12 Pages

  24. K8AK-PA

    12 Pages

  25. K8DS-PA

    12 Pages

  26. K8AK-PW

    12 Pages

  27. K8DS-PU

    12 Pages

  28. K8DS-PZ

    12 Pages

  29. K8AK-TS/PT

    12 Pages

  30. K8AK-LS

    12 Pages

  31. K8AK-TH

    12 Pages

  32. K2CM

    16 Pages

  33. SE

    15 Pages

  34. SAO

    13 Pages

  35. APR-S

    6 Pages

  36. XS5

    25 Pages

  37. XS2

    29 Pages

  38. F92A

    4 Pages

  39. GLS

    3 Pages

  40. TL-L

    5 Pages

  41. V680 series

    68 Pages

  42. V680S Series

    68 Pages

  43. MY

    35 Pages

  44. E3NC-L/-S

    16 Pages

  45. NE0A-SCPU01

    6 Pages

  46. LY

    14 Pages

  47. G2R-[]-S

    11 Pages

  48. G7T

    7 Pages

  49. G2A

    9 Pages

  50. G2A-434

    7 Pages

  51. G2AK

    7 Pages

  52. MK-S

    9 Pages

  53. MK-S(X)

    12 Pages

  54. MM

    17 Pages

  55. MMK

    14 Pages

  56. G4Q

    6 Pages

  57. G7Z

    9 Pages

  58. G7J

    10 Pages

  59. E4B

    12 Pages

  60. E4A-3K

    9 Pages

  61. E4C-UDA

    5 Pages

  62. E6H-C

    5 Pages

  63. E6F-C

    5 Pages

  64. E6D-C

    5 Pages

  65. E6B2-C

    5 Pages

  66. E6A2-C

    5 Pages

  67. NL

    8 Pages

  68. VB

    5 Pages

  69. SC

    5 Pages

  70. D5F

    5 Pages

  71. D5A

    8 Pages

  72. E3S-GS3E4

    3 Pages

  73. E3S-R

    11 Pages

  74. E3S-A

    21 Pages

  75. E3S-CL

    9 Pages

  76. E3ZM-C

    14 Pages

  77. E3T Data Sheet

    26 Pages

  78. E3T Series

    6 Pages

  79. G5 Series

    59 Pages

  80. Sysmac Catalog

    410 Pages

  81. VT-X700

    6 Pages

  82. E5AC-T

    8 Pages

  83. CP1

    12 Pages

  84. CP1E

    12 Pages

  85. MS4800

    40 Pages

  86. VC-DL100

    6 Pages

  87. FZ4 Series

    42 Pages

  88. ZG2

    16 Pages

  89. ZS Series

    32 Pages

  90. ZW Series

    24 Pages

  91. E9NC-T

    2 Pages

  92. NT series

    18 Pages

  93. E2EF

    8 Pages

Archived catalogs

  1. Vision Systems

    20 Pages