You may also be interested in
Scanning probe microscope, Scanning electron microscope, Scanning tunneling microscope, Photoelectron spectrometer, Electron microscope
Text version of the page
How to contact usHeadquarters: Omicron NanoTechnology GmbH Limburger Str. 75 65232 Taunusstein Germany Tel. +49 (0) 61 28 / 987 - 0 Fax +49 (0) 61 28 / 987 - 185 Web: www.omicron.de or www.omicron-instruments.com e-mail: info@omicron.de We have got agents and partners worldwide so please just check our website to fi nd your nearest contact.STM Signal Conversion: Two branch design for signal measurement and signal feedback • ADC resolution 16-bit; 400 kHz sampling rate, switchable low pass (300 Hz, 1 kHz, 3 kHz, 10 kHz, 30 kHz) •MATRIX SPM Control System at a Glance: • STM and Spectroscopy Modes I(V), I(z), I(V,z), dI/dV, d2I/dV2• High-Resolution Non-Contact AFM (Cantilever Beam Defl ection & QPlus) • EFM, KPM, MFM Modes• AFM Force Spectroscopy F(z), $ f(V), $ f(z)• Fast Scanning Capability • Atom Manipulation • Multi-Mode SPM Operation • Access to all Control and Measurement Signals • Flexible Experiment Control Technical Information:Omicron MBE-VariabilityGap voltage range: +/- 10 V and +/- 1 V (standard confi guration) 16-bit resolution, external input for modulation with switchable low pass (300 Hz, 3 kHz, 20 kHz, 56 kHz, full BW) Max. 12 additional ADCs: CRTC: • Maximum spectroscopy acquisition time per spectroscopy point: 19 seconds • Simultaneous over-sampling of all ADCs, maximum over-sampling factor: 2 3 x 4 independent analogue input channels, ADC: 16-bit resolution, DC...400 kHz. Trigger control input/output Simultaneous over-sampling of all ADCs, maximum over-sampling factor: 222 Piezo driver: 22 Output voltage range +/- 135 V low noise (24 bit • 2 independent digital processor inputs, confi gurable link to any digital signal source• 2 independent analogue processor inputs, 16 bit, 400 kHz with switchable low pass: 1 kHz, 3 kHz, 10 kHz, 30 kHz, 100 kHz • External offset input (Z Max. 6 additional DACs: rms / • Hz, 100 kHz bandwidth) Regulator: 3 x 2 independent analogue output channels, DAC: 16-bit resolution, DC ... 400 kHz switchable regeneration low pass (300 Hz, 3 kHz, 30 kHz, 100 kHz) Coarse positioning: 8-channels, variable step size and frequency, remote control and auto-approach • Digital scan generation • Designed for non-orthogonal scans and high speed • Output channels for external devices. • Image rotation • Hardware supported zoom • Maximum data acquisition rate: 200 kSamples simultaneously with up to 4 channels Signal access: Scan Generator: Through front panel mounted BNC connectors. Confi guration includes: MATRIX SPM Control System, Software, SPIP data processing software, Windows XP computer, 2 x 19" LCD monitors, Desk & rack OFFSET ) with switchable low pass: 3 kHz, 10 kHz, 20 kHz, 60 kHz MATRIX SPM Control System 205-V03/Feb.08Printed by Druckerei und Verlag Klaus Koch GmbHSpecifi cations and descriptions contained in this brochure are subject to alteration without notice. |
|