video corpo cad

FSW 6000-7000
3Pages

{{requestButtons}}

Catalog excerpts

FSW 6000-7000 - 1

THERMAL DISPERSION FLOW SWITCHES FSW-6000/7000 Series Starts at FSW-6212, $456, shown smaller than actual size. ߜ Simple to Install and Low Cost ߜ No Moving Parts-Maintenance Free Reliability ߜ Optimal Temperature Compensation— Unaffected by Temperature Gradient ߜ Can Operate in Temperatures up to 120°C (248°F) with Sanitary Option ߜ 300 Bar (4300 psi) Maximum Working Pressure ߜ Chain of 8 LEDsIntegrated Flow Rate/ Setpoint Indication ߜ Can Be Used as a Level Switch The FSW-6000/7000 Series are thermal flow switch monitors designed to monitor flow status and also used to detect level of liquids, air and gas. A chain of 8 LEDs gives the user a visual indication of the flow rate. In addition, there is also a dichromatic LED, which shows the switch point status of the unit. The sensing element and connection of the FSW-6000/7000 Series are made with 316 SS and can be coated with PTFE as an option. The standard enclosure is glass-filled nylon and is also available in an aluminum enclosure for hazardous environments. The FSW-6000/7000 Series can be made with a great variety of process connections such as threaded, flange, or sanitary. The FSW-6000/7000 Series line of thermal flow switch monitors is based on the principle of thermal dispersion. A typical configuration uses two platinum Resistance Temperature Detectors (RTDs) set within the tip of the sensor. One RTD is heated a few degrees above the temperature of the medium and the other RTD is used as a reference, sensing the actual process temperature. The second RTD also monitors the temperature of the medium, as any changes in temperature must be compensated for in the first RTD. As the process medium flows over the tip of the sensor it disperses some of the B-85 heat from the first RTD. The temperature change between the two RTD's signals the probe’s electronics and the switch changes state once the setpoint has reached. The FSW-6000/7000 Series may be installed in a pipe or tank using the thread or connection provided. Use only the hexagon when tightening to achieve a seal, do not use the body. The body should be rotated after tightening to leave the cable gland in suitable orientation. The FSW-6000/7000 Series is not affected by its fixing position so it may be installed at any angle around the pipe. However, it is recommended that with horizontal pipe runs the sensor should be installed on the side, into the middle of the pipe. In vertical pipes, the FSW-6000/7000 Series should be installed when there is flow in an upward direction against gravity. Care should be taken when installing the sensor that the probe extends clear of the pipe’s internal wall and is fully immersed into the flow. In pipes with smaller diameters, some care should also be taken so that the sensor is not screwed too far into the line.

Open the catalog to page 1
FSW 6000-7000 - 2

SPECIFICATIONS Accuracy: ±10% of setpoint Repeatability: ±1% of setpoint Power Supply: FSW-6000: 85 to 240 Vac (50/60 Hz) FSW-7000: 24 Vdc ±10% Process Connection: ⁄2 to 11⁄2 NPT, Tri-GripTM, or flange (others available, consult Flow Engineering Department) Output: 250 Vac SPDT 5 A relay Switch Point Adjustment: Potentiometer Max Start up Delay: 12 seconds Switching Range: 3 cm/s to 3 m/s (0.09 to 9.84 ft/sec) (liquid), 5 cm/sec to 15 m/sec (0.16 to 49 ft/sec) (gas) Temperature Range: Process: -20 to 80°C (-4 to176°F) [sanitary option to 120°C (248°F) for CIP] Operating: -20 to 60°C (-4...

Open the catalog to page 2
FSW 6000-7000 - 3

Your One-Stop Source for Process Measurement and Control! UNITED STATES Deckenpfronn, Germany UNITED KINGDOM Manchester, England More than 100,000 Products Available! Calibrators, Connectors, General Test and Measurement Instruments, Handheld Instruments for Temperature Measurement, Ice Point References, Indicating Labels, Crayons, Cements and Lacquers, Infrared Temperature Measurement Instruments, Recorders, Relative Humidity Measurement Instruments, PT100 Probes, PT100 Elements, Temperature & Process Meters, Timers and Counters, Temperature and Process Controllers and Power Switching...

Open the catalog to page 3

All OMEGA catalogs and technical brochures

  1. WTS Series

    4 Pages

  2. DPG280

    2 Pages

  3. Model H

    1 Pages

  4. HHAQ-104

    1 Pages

  5. DOTX441

    1 Pages

  6. TXDIN1600s

    2 Pages

  7. M12

    1 Pages

  8. AHPF Series

    1 Pages

  9. RFH Series

    2 Pages

  10. HHM10

    6 Pages

  11. RDXL8

    2 Pages

  12. OS-MINIHUB

    4 Pages

  13. RHCM-40-PL-P

    2 Pages

  14. CSMSTRLE

    3 Pages

  15. ADAM-5000

    7 Pages

  16. KE Series

    1 Pages

  17. SRM Series

    3 Pages

  18. SRL Series

    3 Pages

  19. PHH-SD1

    2 Pages

  20. PHH222

    1 Pages

  21. PHH224

    1 Pages

  22. PHH720

    1 Pages

  23. PHH830

    2 Pages

  24. PHH-126

    1 Pages

  25. PHH-127

    1 Pages

  26. PHH-128

    1 Pages

  27. PHH-37

    1 Pages

  28. PHH-715

    2 Pages

  29. PHH103B

    1 Pages

  30. BB-5

    2 Pages

  31. BB-2A

    2 Pages

  32. CA 150

    5 Pages

  33. CL 110

    2 Pages

  34. CL 1600

    2 Pages

  35. CL 1201

    2 Pages

  36. CL 355A

    2 Pages

  37. FL 500

    2 Pages

  38. FL 500WW

    2 Pages

  39. FL-X

    2 Pages

  40. FPR 100

    3 Pages

  41. FSW500

    2 Pages

  42. FSW 420- 430

    2 Pages

  43. CDTX90

    6 Pages

  44. DRP 8500

    3 Pages

  45. DP 3300

    2 Pages

  46. DP119

    1 Pages

  47. HE-X Series

    3 Pages

  48. HE359 Series

    3 Pages

  49. RD4

    2 Pages

  50. DPi

    3 Pages

  51. HH311

    2 Pages

  52. MP1

    1 Pages

  53. HFS

    2 Pages

  54. CO

    2 Pages

  55. WT

    2 Pages

Archived catalogs

  1. 6M Series

    2 Pages