DC Power Line On-Off Surge ZP , CP - Okaya - #1

/ 3


catalogue search
DC Power Line On-Off Surge ZP , CP - Okaya
P. 01
DC Power Line On-Off Surge ZP , CP - Okaya
P. 02
DC Power Line On-Off Surge ZP , CP - Okaya
P. 03
Pages:
DC Power Line On-Off Surge ZP , CP - Okaya


See other catalogues for Okaya

Text version of the page
RSSA
SILICON SURGE ABSORBER @ OKAYA M
RSSA
The Silicon Surge Absorber is available in five series that support the countermeasure against a wide range of surge from low to high, including electrostatic discharges and lightning surges. The device may also be used as a constant voltage device where high voltage or high power is required.
• Breakdown Voltage (Vbr)
Voltage at which avalanche current may begin to flow, normally the voltage between the surge absorber's leads when 1mA of current is applied.
* Standoff Voltage (Vwm)
A maximun voltage that can be applied to the surge absorber continuously.
• Reverse Leakage Current (Ir)
A maximum current flowing through the surge absorber when the standoff voltage is applied to the surge absorber.
* Peak Surge Current (I ppm )
A maximum surge current that can flow through the surge absorber, but not repetitively. The waveforn in the table is 8/20p,sec.
* Peak Clamp Voltage (Vcl)
a maximum voltage that may be generated between the surge absorber's leads when the peak surge current is applied to the surge absorber.
• Mavimum Allowable Power (Pppm )
(Pppm)= (Vppm)x (Vcl)
• Fast response to rapid surge (1fJ-12sec).
• Almost no performance degradation against repetitive surge.
• Very low internal resistance during operation.
• Very small leak current.
• Mesa chip design provides high invulnerability to impulse surges.
ctrical Specifications
VCL VBRVWM
Voltage vs. Current characteristics of model CP (two-way type)
Applications
DC/DC converter
_ Voltage VwmVbrVcl max
Voltage vs. Current characteristics of model ZP (one-way type)
Battery
a) Protection against switching surge
b) Protection of DC/CD converter
Typical capacitance between absorber's lead vs. Breakdown voltage
-**-r
Zero Bias (f= 100kHz)
=
ll\
==zPo0
)
~>::
-
-
\~
2
\
c
001
fi"
z
ui
3(
'1
0 0
s
p
=
=
=
=
=
=
-
-
-
>
<
\
s
S\
s
=
=
=
1
s
■s
s,
s:
>
S
■s
I
tw
Ml
7777? 71717
c) Protection of interface RS485A from lightning surge (surge absorbed-component surge protection)
° 10000
D1 ■ D2 D3 • D4 ■
I
8 1000
J7ĎĎ 77ft
SG-
e) Protection of RS-485-A lightning surge
e) Protection of data line (arrayed surge absorbers)
10
100 Breakdown Voltage (V)
m

pageCatalog pdf di En 2012-05-22-31