| | | Additional LIBS Components | | |
| | | |
| | | LIBS Sample Chamber | | |
| | | |
| | | The LIBS-SC Sample Chamber is a key component of a LIBS system and is designed to perform various functions safely and in clear view of the sample. The LIBS-SC has an eyewear-safe enclosure. The chamber has a safety-interlock so the laser will not fire when the door is open. It houses a manually controlled x-y-z stage and provides illumination for the optional LIBS-IM-USB Imaging Module. The LIBS-SC has an inert gas induction port and a suction nozzle to remove particulates. In addition, you have the ability to | | |
| | | |
| | | Stages: Manual x-y-z stage Sample size: 6.5 cm x 6.5 cm x 4 cm max. Laser safety shield: OD 6 for 1.064 mm laser energy (call for other | | |
| | | focus the laser to a 40 spot size. The sample chamber is designed for use with the Big Sky Industrial lasers we resell (see below for laser | | |
| | | The LIBS-SC includes an evacuation system that removes material from the sample area. You also can feed gases such as argon into the chamber. Flooding the chamber with an inert gas provides greater sensitivity for many elements. | | |
| | | |
| | | details). If you wish to use the LIBS-SC with a different laser, please contact Ocean Optics. LIBS-SC: $9,800 | | wavelengths) | |
| | | |
| | | Internal optics: | | 25 mm diameter focusing lens,
| |
| | | |
| | | 75 mm focal length supplied Ablation spot size: approximately 40 urn | | |
| | | |
| | | |
| | | |
| | | LIBS Imaging Module for Pinpoint Analysis | | |
| | | CD TJ CD 0 ct 1 0 3 CD CD 1 | | |
| | | |
| | | ] | | |
| | | The LIBS-IM-USB Imaging Module directly attaches to the LIBS-SC Sample Chamber to enable users to magnify a sample image and to establish a laser ablation target on the sample. The camera is also useful when you want to adjust the laser focus at the surface of the sample, or above or below the sample surface. When used with the LIBS-SC and laser, the LIBS-IM-USB and laser are in the same focal plane enabling precise, rapid and convenient laser focus. The USB-enabled color camera captures pre- and post-ablation images of the sample and provides up | | |
| | | Specifications | | |
| | | |
| | | |
| | | Interface: USB 2.0 (480 Mb/sec)_ Power:_USB 5 VDC, max. 180 mA_ Frame size: 1280 x 1024, 640 x 480, 320 x 240, _160 x 120_ Data output: RGB 24 bit_ Requirements: -- Windows XP Professional SP1 -- Support of Direct X -- Driver compatible Windows driver model (WDM) -- SDK iREZ WDM library -- 3.2 GHz or higher processor -- 1 GB recommended memory -- 10 GB free hard disk space -- Rocket-fast GeForce 4200Ti or better video card recommended | | |
| | | |
| | | CD < CD CD 3 CD | | |
| | | This image is the "O" text "Quarter Dollar" coin. | | the a U.S. | | |
| | | |
| | | to | | 1280 x 1024 pixel resolution. | | |
| | | LIBS-IM-USB: $8,000 | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | LIBS Laser Options We offer two LIBS25000 laser power options from industry leader Big Sky Laser Technologies. Laser ablation and plasma formation are very specific to the sample matrix, and therefore the power requirements will vary by sample type. For most applications we employ a Q-switched 1064 nm Nd:Yag laser, and for maximum versatility, we recommend a 200 mJ laser with attenuator to adjust the laser power according to the sample matrix. The choice of laser power and wavelength depend on the material being analyzed and the sample's tolerable damage threshold. The LIBS-LASER is a 50 mJ CFR Nd:YAG laser for metal and thin film samples. The LIBS-LAS200MJ is a 200 mJ CFR Nd:YAG laser for most all other materials. | | |
| | | CD CD C TJ CD | | |
| | | |
| | | |
| | | $14,500 $22,500 | | |
| | | LIBS-LASER: LIBS-LAS200MJ: | | |
| | | |
| | | |
| | | LIBS Versus Other Technologies | | |
| | | |
| | | | | | | | | | | | | | Parameter | LIBS | SEM/EDS | XRF | LA-ICP-MS | EPMA | | | | Sample depth: | ~50-100 |jm | ~5 jm | ~100 jm | ~80 jm | <1 urn | | | | Sensitivity: | 10-50 ppm | 1000 ppm | 100 ppm | <1 ppm | 100 ppm | | | | Precision: | Fair-good | Poor | Fair-good | Excellent | Fair | | | | Accuracy: | Semi-quantitative | Qualitative | Semi-quantitative | Quantitative | Semi-quantitative | | | | Analysis time: | Fast | Slow | Very slow | Slow | Slow | | | | Sample consump: | almost non-destructive | non-destructive | non-destructive | almost non-destructive | non-destructive | | | | Complexity: | Easy to use | Easy to use | Easy to use | Complicated | Complicated | | | | Discrimination: | Good | Poor | Good | Excellent | Fair | | | | Cost: | $60,000 | $120,000 | $120,000 | $250,000 | $600,000 | | | | | | | | | | | | | |
| | | |